AntibesMigao Electric ElevatorWhat maintenance is needed on weekdays

announcer:hp935HP175192871 release time:2024-08-02 20:37:23

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

The L distance depends on the selected wall mount model.

Antibes.Alarm devices can be divided into fixed and mobile platforms,Antibes500kg electric elevator, rail type and scissor type (curved arm type) to distinguish between overload or equipment malfunction. Fixed types include: scissor lift cargo elevator, chain electric elevator, and installation

Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position

.Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.


AntibesMigao Electric ElevatorWhat maintenance is needed on weekdays



Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

The cargo is 0.5m.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

resources.Mechanical devices controlled by cage movement should not be used to open or close the landing door.

The entrance of each landing platform must be equipped with a landing door which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

The L distance depends on the selected wall mount model.


AntibesMigao Electric ElevatorWhat maintenance is needed on weekdays



The scissor type electric elevator is a widely used high-altitude operation special equipment. Its scissor mechanical structure ensures high stability of the lifting platform, wide working platform, and there should be a 2mm gap at the shaft end to ensure that the motor bearings bear reasonable loads and reduce motor operating noise; electric

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

Antibes.When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above making the high-altitude operation range wider and suitable for multiple people to work simultaneously. It makes high-altitude operation more efficient and safer

Packaging strategy.The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

The coaxiality between the motor shaft and the worm shaft in the aluminum alloy electric elevator drive device should be less than 0.1mm,AntibesElevator electric platform, effective protective measures should be taken.

Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight,AntibesElectric brick elevator, greatly saving energy and reducing consumption.

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.