AsperniScissor fork hydraulic lifting tableFeatures and scope of application

announcer:hp530HP141750488 release time:2024-07-29 10:58:23

Therefore, the wholesale manufacturers of hydraulic elevators remind that there are three main ways to adjust the speed control circuit: throttling speed control circuit: quantitative pump oil supply, the oil is supplied by the pressure limiting variable pump, and the flow rate into the actuator is adjusted by the flow valve to adapt the flow rate of the variable pump to the regulated flow rate of the speed control valve.

The main device does not engage. When this fault occurs check whether the three-phase power supply is normal, whether the internal and external emergency stop button switches, the electric lock switch are turned on, whether the three-phase electrical phase sequence is correct, and whether the relay working indicator light is on.

Asperni.In winter, when working outdoors at heights below minus 10 degrees Celsius, heating rest areas should be set up near the construction area if necessary. Heating equipment should be managed by dedicated personnel and attention should be paid to fire prevention.

Oil leakage from the oil cylinder: If it is a problem with the sealing ring, replace the sealing ring. If there are debris or debris on the oil cylinder, it is recommended to replace it with a new one.

.Voltage too low: Measure the starter voltage, with an allowable fluctuation range of± 10%.

Regularly check whether each organization is functioning properly and whether there is noise. If problems are found, they should be promptly cleaned up.

Remove the hydraulic oil tank filler cap, filter cover, inspection hole,AsperniHandmade children's hydraulic lifting platform, hydraulic oil pipe and other parts to avoid dust when removing the system oil pipe. Clean the disassembled parts before opening them. When disassembling the hydraulic oil tank filler cap, first remove the soil around the tank cap, loosen the tank cap, and remove any remaining debris from the joint (do not rinse with water to prevent water from seeping into the tank). After confirming cleaning, open the tank cap.


AsperniScissor fork hydraulic lifting tableFeatures and scope of application



Protective device: In case of power or oil circuit failure there should be a safety rope to prevent the workbench from falling out of control. (Allow controlled descent)

Compare the measurement curves and then go to the variable displacement pump or variable speed motor. Long term targeting all types of high-priced elevator manufacturers nationwide with reasonable prices and comprehensive services,AsperniMobile hydraulic lifting platform, we have gained recognition from our customers

If the circuit of the device is not disconnected or lowered, it is necessary to check the fuse for repair and replacement.

packing.The lifting platform is a multifunctional heavy loading and unloading mechanical equipment, which can be divided into fixed and mobile, guide rail and curved arm types. Fixed types include scissor elevators, chain elevators, and attached electric construction platforms.

When the hydraulic oil of the equipment is insufficient, it will not cause lifting. At this point, you only need to add enough hydraulic oil to run.

Stability: The workbench should evenly withstand 125% of the MAX load capacity and be stable at the MAX elevation.


AsperniScissor fork hydraulic lifting tableFeatures and scope of application



The optional configurations of a fixed lifting platform include manual hydraulic power, movable flip plates that are easy to overlap with surrounding facilities, rolling or motorized roller tracks, safety contact bars to prevent foot rolling, organ type safety protective covers, manual or motorized rotating workbenches, hydraulic overturning workbenches,AsperniCustomized hydraulic lifting platform, safety support rods to prevent the lifting platform from falling, stainless steel safety nets, electric or hydraulic lifting platform walking power systems, and universal ball countertops.

Safety and health.The speed circuit is the circuit that switches the motion speed and speed of the actuator in the hydraulic system of the guide rail hydraulic lifting platform. Mainly including valves, pumps, and speed switching circuits.

A lifting platform is a lifting device that lifts people or goods to a certain height. When vertical conveying is carried out in logistics systems such as factories and automatic warehouses, various flat conveying equipment is often installed on the lifting platform as a connecting device for conveying lines at different heights. Usually driven by hydraulic pressure, it is called a hydraulic lifting platform. In addition to being used for transporting goods at different heights, it is widely used for high-altitude installation, maintenance and other operations.

Regularly check all wires and cables for damage. It is necessary to wrap and replace the damaged parts in a timely manner.

Asperni.When using hydraulic elevators, frequent inspections and maintenance should be carried out, which not only extends the service life of the hydraulic elevator, but also enables it to exert greater power during operation. Of course, hydraulic elevators also have their own regular repair times and protection methods: regular protection (carried out per shift).

Ensure that there is a suitable power supply at the installation site, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, and the hydraulic cargo elevator construction site should be equipped with a fire extinguisher to prevent welding operations from causing fires. When selecting a leakage switch, it should be suitable for the operating power.

When installing, disassembling, and adjusting the rotating mechanism, attention should be paid to ensuring that the middle line is parallel to the middle line of the gear, and its meshing surface is not less than 70%. The meshing clearance should be suitable for the brakes of each mechanism. The clearance between the brake wheels should be regularly checked and adjusted to ensure its flexibility and reliability. There must be no dirt on the friction surface and it must be cleaned with gasoline or diluent.