BotanzaFoot hydraulic lifting platform vehicleInspection requirements

announcer:hp695HP135175170 release time:2024-07-13 15:31:33

Outdoor elevators and factory cargo elevators are heavy lifting mechanical equipment. Outdoor elevators are used for transporting goods between floors of buildings, and are specialized hydraulic cargo elevator products. They are mainly used for transporting goods up and down between various working floors; Vertical garage and car lift between garage floors. The hydraulic system of the product is equipped with anti fall and overload protection devices, and operation buttons can be set on each floor and lifting platform workbench to achieve multi-point operation.

The load capacity of goods and the tonnage of goods transported at once also affect the speed of lifting and lowering. Achieving the excellent value of the lifting platform for transporting goods is a guarantee of speed. If the weight is too heavy, it affects the speed. If the goods are too light, it also affects the normal transportation time.

Botanza.The oil filter is severely blocked; The solution is to clean the oil filter or replace the hydraulic oil. Long term lifting scissors fork lift manufacturers and other various brand products, with complete designated products and guaranteed quality

Regular inspection and maintenance, eliminating hidden dangers and troubleshooting are beneficial for improving work efficiency, extending equipment service life, and ensuring the safety performance of elevators.

.For the safety performance of high-altitude work platforms, it is necessary to have production technology, scientific processes, and strict management to ensure production. When in use, people, the environment, and machines are the three major links of high-altitude operations, and safety is the basic condition to ensure the smooth progress of high-altitude operations. In the following text, Jiuyi briefly describes the precautions for using high-altitude operation platforms: high-altitude operators must hold a health certificate. Individuals suffering from intentional,BotanzaHydraulic lifting platform, high-pressure, or mental illness are not allowed to engage in high-altitude work tasks. Staff are not allowed to engage in high-altitude work while drinking alcohol or feeling mentally drained.

Carefully prepare a special construction plan for installation and provide technical disclosure to the installation personnel. I have been engaged in various types of scissor lift manufacturers and other materials for many years, and operate with integrity. Welcome to call!

Good stability: The overflow valve can prevent excessive system pressure during upward movement. Emergency manual valve: In case of power failure, it can cause the elevator car to descend to the nearest floor position and open the door. Manual pump: When the system malfunctions the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position; Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops.


BotanzaFoot hydraulic lifting platform vehicleInspection requirements



Elevators are now very popular among people and can easily transport goods to high-rise buildings. Among them, hydraulic elevators are more popular among people, during normal work, it is important to pay attention to the lifting speed of hydraulic elevators and avoid making mistakes. So what factors will affect the lifting speed of hydraulic elevators?

The above introduction to common faults of hydraulic boarding bridges can be said to be very detailed. I hope everyone can respond well to various problems after reading it.

The inconsistent rotation axis of the support rod in the middle of the hydraulic lifting platform results in the lifting platform being unable to function properly, causing serious damage to the platform and causing the table to tilt. Please carefully check that the general shear type high-altitude work platform was not strictly tested for tilt before leaving the factory, and was put into the market, causing many accidents. For small enterprises, they are not very concerned about this aspect of tilt detection, This is also why there are such a large number of lifting equipment with this problem. The problems with the oil cylinder and power unit system are often due to insufficient power and substandard oil cylinder quality, which are also very important issues for enterprises themselves.

Supply chain quality management.The daily maintenance of guide rail type lifting equipment should pay attention to regular inspection and maintenance, eliminate hidden dangers, eliminate faults, and achieve these benefits for improving work efficiency, extending equipment service life, and ensuring the safety performance of the elevator.

Mobile elevators are generally used in skyscrapers where electric elevators are used, so fast elevators are needed. First go to the high-rise sky lobby (high-rise elevator lobby, Skylobby) from the ground, and then transfer to the ordinary elevator to the destination. Some new elevators use elevator pre calling systems, which can pre call designated floors in the lobby. These passenger elevators can be decorated beautifully according to customer needs. Some passenger elevators are also equipped with air conditioning and television while others are set up in the cabin, so that customers can enjoy the scenery outside while riding.

The daily maintenance of guide rail type lifting equipment should pay attention to regular inspection and maintenance, eliminate hidden dangers, eliminate faults, extending equipment service life, and ensuring the safety performance of the elevator.


BotanzaFoot hydraulic lifting platform vehicleInspection requirements



The guide rail type cargo elevator has been inspected and debugged before leaving the factory, and all technical indicators have met the design requirements. When in use, only the power supply needs to be connected, and the hydraulic and electrical systems do not need to be adjusted.

Word of mouth recommendation.When encountering overheating in the hydraulic elevator motor, it is necessary to stop it in a timely manner, eliminate the fault, and continue running. The motor bearings should be in good condition.

When the lowering valve is open and the lowering button is released, use a voltmeter to check whether the lowering valve is energized. If there is no power, check the circuit and eliminate the fault; If there is electricity, do not open the packaging too early. This can easily lead to premature bearing contamination, which can lead to premature bearing damage. Additionally, ensure that the installation environment is clean and do not bring iron filings, dust, and other objects into the bearings. Even small dust particles can cause premature bearing damage, Prolonged use can also affect the running in between bearings, leading to a decrease in the lifespan of the elevator.

Botanza.Regular refueling is necessary for maintenance of the elevator: During the use of the elevator, due to the large load, there is also significant friction between various components, especially the elevator chain and elevator shaft pins. It is necessary to ensure that an appropriate amount of oil is added before each use to ensure flexibility and non jamming during operation. If the elevator is in operation and once&quo; appears; Squeak and Squeak&# quo; The friction sound can be basically determined to be due to a lack of oil in the elevator. It is necessary to immediately stop working and investigate the cause,BotanzaHydraulic scissor type lifting platform, and cannot forcibly operate,BotanzaHydraulic lifting platform for loading, which can easily cause unforeseeable hidden dangers. Summary: Regular refueling is not allowed when maintaining the elevator.

When installing, disassembling, and adjusting the rotating mechanism, it is important to ensure that the centerline of the reducer of the rotating mechanism is parallel to the centerline of the gear, and its meshing surface is not less than 70%. The meshing clearance should be suitable.

The guide rail type cargo elevator has been inspected and debugged before leaving the factory, and all technical indicators have met the design requirements. When in use, only the power supply needs to be connected and the hydraulic and electrical systems do not need to be adjusted.