Komarom 10 meter electric lifting platformProduction steps and inspection requirements

announcer:hp935HP175192871 release time:2024-06-28 16:03:47

measures should be taken to make it meet the requirements the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Komarom .Lower limit switch: In normal working state, before the suspension cage touches the buffer, the lower limit switch first acts.

The counterweight guide rail should meet the specification requirements.

.Implementing multiple shifts of homework should fill in and submit records according to regulations.

Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented, and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

The use of standard section connecting bolts should comply with the user manual and specification requirements.


Komarom 10 meter electric lifting platformProduction steps and inspection requirements



Acceptance: Concrete strength grade C30, strength testing report.

Stop.

Setting requirements: The landing door should be standardized and tooled.

Affordable price.During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise,Komarom Micro electric hydraulic elevator, measures should be taken to make it meet the requirements,Komarom Electric elevator 8 meters, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.


Komarom 10 meter electric lifting platformProduction steps and inspection requirements



Remind customers that there are still many areas to pay attention to when maintaining and maintaining the lifting platform. We also hope that customers and friends can pay more attention when using it to ensure the safety of personnel and property, regularly maintain and extend its service life, and create greater benefits for the enterprise. What is the matching degree of electric elevators? Everyone has always been confused. In short,Komarom Electric scissors elevator, the matching degree of electric elevators is how the height of the electric elevator can be combined with the operating height. Electric elevators are not used frequently, so we must make it clear based on the actual operating height and actual load capacity when using electric elevators. If the frequency is too high, We suggest considering purchasing a guide rail electric elevator or a scissor fork electric elevator. The scissor fork electric elevator can achieve a maximum load capacity of 100 tons, which effectively solves the problem of load capacity. If the frequency of use is too high and the height is relatively high, we recommend using a guide rail electric elevator. This type of electric elevator is not easy to malfunction under high-frequency operation, By solving the load capacity and frequency of use the matching problem of electric elevators is effectively solved. Concept of electric elevator rotary valve: The electric elevator rotary valve is a type of valve that quickly opens and closes, and the rotary valve can reduce oil pipeline channels and optimize line settings.

average method.Spiral electric lifting mechanism: With all the functions of a regular lifting platform, the main feature is that the equipment occupies a small foundation pit and has a large stroke. The equipment has a height of only 200-500mm and a travel distance of up to 14m. It is particularly suitable for buildings with stages built on two or more floors due to space constraints.

Items and other miscellaneous items.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Komarom .The foundation base or embedded parts should be fully embedded in the concrete foundation plate.

Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, and report any problems found to the user unit.

The setting of the cable guide frame should comply with the user manual and regulatory requirements.