Genhe RiverElectric elevator lifting by 4 meters,

Installation verticality deviation guide rail frame erection height, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, as specified in the above table.

Genhe River.The device should be used within the valid calibration period and operate effectively and reliably. The anti fall safety device should have a valid inspection certificate (or inspection report), and the validity period should not exceed 1 year. Anti fall safety devices have been manufactured for five years

Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

.The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s passenger car doors, the safety distance can be 0.40m.

The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.

The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.


Genhe RiverElectric elevator batteryIndustry notes



Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

Construction electric elevators should be equipped with lower limit switches that are sensitive and reliable.

Implementing multiple shifts of homework should fill in and submit records according to regulations.

install.Installation verticality deviation guide rail frame erection height, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.


Genhe RiverElectric elevator batteryIndustry notes



According to the needs of different performance genres, using an orchestra pit lift can combine a framed stage with a large lip or even an extended stage. In an experimental theater, using a lift can make the theater have various forms such as an end stage, an extended stage, an island stage, an intermediate stage, a T-shaped stage, or a hall.

Sampling inspection.Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

Before installing the construction electric elevator, the foundation should be inspected and approved before installation.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Genhe River.Mechanical devices controlled by cage movement should not be used to open or close the landing door.

The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver,Genhe RiverElectric automatic elevator, the landing door shall not be opened.

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.