DongzhouScissor fork electric elevatorWhat are the advantages of the product

announcer:hp935HP175192871 release time:2024-05-16 15:31:32

During normal operation,DongzhouElectric pull rod elevator, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

Dongzhou.And the decoration team is also using aluminum alloy electric elevators. What safety considerations should we consider during the use process? Many manufacturers have not clearly indicated it. Today, the mechanical editor will talk to you about aluminum alloys

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

.The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, the landing door shall not be opened.

Emergency manual valve: In case of power failure it can cause the car to descend to the nearest floor position and open the door

Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.


DongzhouScissor fork electric elevatorWhat are the advantages of the product



Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

The movement of its related components is direct.

Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.

Job description.Work is essential, and the main protective accessories include safety belts, guardrails,DongzhouElectric elevator, protective covers, platforms and stairs, etc.

Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).


DongzhouScissor fork electric elevatorWhat are the advantages of the product



The setting of the cable guide frame should comply with the user manual and regulatory requirements.

OK or not?.Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position

When a single steel wire rope is excessively stretched the Electrical safety device shall stop the operation of the electric lift.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

Dongzhou.The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, throttle valve, and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Work is essential, and the main protective accessories include safety belts, guardrails, protective covers, platforms and stairs, etc.