TodelgekoMobile electric hydraulic elevatorDelivery

announcer:hp935HP175192871 release time:2024-05-08 16:51:44

Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, as specified in the above table.

Todelgeko.The detailed reason why water cannot be used to flush the hydraulic station is that doing so will corrode the oil tank in the hydraulic station, and once water is mixed in the hydraulic station, the damage to the hydraulic system is very large. Therefore, it will simply form pipeline corrosion, water vaporization, and other phenomena that can cause adverse effects or results for hydraulic electric elevators. Therefore, it is necessary to prevent such actions to ensure the normal operation and service life of the hydraulic station.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

.When the wall bracket adopts non matching standard products, design calculations should be carried out.

The landing door should meet the requirements of the specifications and achieve standardization.

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.


TodelgekoMobile electric hydraulic elevatorDelivery



The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

A lifting platform with specifications ranging in height from 1 meter to 20 meters.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Bidding.Monthly maintenance and inspection of hydraulic lifting platform rollers, intermediate shafts and bearings, oil cylinder pin shafts and bearings,TodelgekoRechargeable electric elevator,TodelgekoHand propelled electric elevator, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark,TodelgekoElectric elevator lifting platform, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.

When the landing door is closed, the full width of the lifting passage opening should be covered.


TodelgekoMobile electric hydraulic elevatorDelivery



The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Latest consultation.Mechanical devices controlled by cage movement should not be used to open or close the landing door.

High altitude operations and maintenance in areas such as repair, logistics, electricity, transportation, petroleum, chemical hotel, sports center, mining, and enterprise. The lifting system of the lifting platform is driven by hydraulic pressure, also known as hydraulic lifting

The hydraulic oil forms a certain pressure by the vane pump, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

Todelgeko.The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology, smooth lifting and low noise.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

Before installation, the installation unit should confirm that the foundation, foundation bearing capacity embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form concealed engineering acceptance form, and concrete strength report.