Drain all the hydraulic oil in the oil tank, open the oil tank, take out the oil suction filter, clean it, and return it to the oil tank. Install it in its original position. Fill the fuel tank with new oil.

Remove and disassemble the lowering valve, blow the valve core clean with compressed air, and then reinstall it.

Aachen.When using an electric lifting platform, there are many details that need to be noted, such as placing it on a flat surface during use to prevent tipping during work. In addition, what are the precautions for using electric lifting platforms?

When the motor overheats it should be stopped immediately, and after troubleshooting, it should continue to operate. The motor bearings should be in good condition.

.After working for 10000 hours, repair the mechanical and electrical systems of the elevator.

Troubleshooting: When the elevator power light is turned on, press the up button, the motor rotates, but the lifting platform does not rise. This may be due to the reversal of the motor after the three-phase power supply is connected just change the two phase wires of the heavy machine.

Regularly check all wires and cables for damage,AachenSingle column hydraulic lifting platform, and promptly wrap and replace the damaged parts.


AachenHydraulic lifting platform fixed typeNew device can improve performance



Firstly, an obvious advantage is its high safety performance. The guide rail hydraulic lifting platform adopts heavy-duty chain transmission, hydraulic explosion-proof oil pipes, safety devices to prevent overloading, multiple limit switch protection, door and power outage protection, leakage protection, and multi-layer building interaction. Therefore, the safety factor of the guide rail hydraulic lifting platform is still very high, much higher than that of ordinary platforms.

Everyone knows that many industries use hydraulic elevators, and when using them, it is necessary to ensure the stability of the machine. If the machine is unstable, it will have a significant impact during use. So, what details cannot be ignored during the use of hydraulic elevators?

Regularly check all wires and cables for damage, and promptly wrap and replace the damaged parts.

manufacturer.After working for 10000 hours, repair the mechanical and electrical systems of the elevator.

Maintenance time regulations for hydraulic elevators: After 1500 hours of daily maintenance of the elevator, repair the mechanical and electrical systems.

The current fixed hydraulic elevators are mainly enclosed or meshed lifting channels surrounded by buildings and light steel structures, and use hydraulic cylinders to lift the platform. Its main components are as follows: the lifting passage part: a closed or mesh frame surrounded by buildings or light steel structures, a fixed hydraulic lifting platform with steel guide rails installed on both sides of the internal driving part: it is equipped with hydraulic driving motors, oil pumps, safety valves, fixed hydraulic lifting platform speed control valves The small oil tank cylinder part of hydraulic components such as directional valves: composed of one or more cylinders of a lifting cylinder,AachenHydraulic lifting platform fixed type, a straight top platform, or a lifting shear fork frame, forming a door system. The closed or mesh platform door or door system consists of a steel structure with manual and automatic doors. Generally, open platforms do not have doors. The electrical part is composed of power, signal, safety, lighting, There are enclosed (i.e. cabin type) or open types, with guide rollers or guide shoes on both sides. The platform bottom can be connected to the lifting cylinder or lifting scissor type steel frame auxiliary parts, which are composed of hydraulic pipe fittings, pipelines, pressure gauges, and steel structure bases; Safety devices: safety valves, limit limits, rupture valves, emergency switches, and electrical short circuit protection.


AachenHydraulic lifting platform fixed typeNew device can improve performance



Everyone knows that construction elevators are used during the construction process because they have stability, are sturdy and reliable during use, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform, and the lifting of goods should try to maintain a stable and uniform speed.

Everyone knows that many industries use hydraulic elevators, and when using them, it is necessary to ensure the stability of the machine. If the machine is unstable, it will have a significant impact during use. So, what details cannot be ignored during the use of hydraulic elevators?

Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

Aachen.The purpose of the stage elevator: The telescopic stage adopts an effective guidance system, which reduces the gap between the telescopic stage and the fixed stage during the translation process, ensures smooth operation, and continuously changes speed. The synchronous device adopts a low speed and large torque drive, making the stage parallel, and retractable in place during the stretching process, cinemas, multifunctional halls, studios, cultural sports venues, hotels, etc.

The loading and unloading mobile boarding bridge has become a very common structural form in modern logistics sites. It is the point and endpoint of the enterprise logistics chain, and a loading and unloading operation platform for enterprises to quickly and turnover products and goods. The height of the loading and unloading operation platform is fixed but there is always a certain height difference or gap between the transportation vehicles and the loading and unloading platform due to the height of the carriage. Causing the forklift to be unable to enter and exit the transportation vehicle for direct loading and unloading of goods. Use the boarding bridge to provide reliable connections. Enable forklift trucks to quickly enter and exit transportation vehicles for loading and unloading operations.

If the elevator malfunctions, non electrical professionals are not allowed to disassemble and assemble electrical appliances at will to prevent accidental connection or electric shock!