EmerodElectric tatami elevatorOperating procedures for installation and disassembly of lifting equipment

announcer:hp935HP175192871 release time:2024-04-09 11:16:59

hands

Stage equipment safety door. To prevent personnel from extending their heads, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

Emerod.Unloading platform and attached electric construction platform, etc.

A complete lifting platform accessory can be selected and customized according to different places, venues, and environmental usage conditions. Meet the needs of different users. So why lifting platforms can be used and installed in so many industries and places is because they can achieve multi-purpose, demonstrate multifunctional, meet various different needs, and win market demand. In modern industrial transportation processes, lifting platforms have begun to play an increasingly important role, whether in airports, warehouses,EmerodElectric pull rod elevator, floors workshops and other places that require rapid loading and unloading of goods, they have played a very practical value, It has also brought great contributions to the entire industry and even the entire economic development. However, long-term operation and use of these devices inevitably lead to wear and consumption, and regular maintenance and upkeep are essential. Otherwise, both work efficiency and utilization rate will decrease, and at that time, the gains and losses will outweigh the losses.

.Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

Stage equipment safety door. To prevent personnel from extending their heads, hands and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).


EmerodElectric tatami elevatorOperating procedures for installation and disassembly of lifting equipment



It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easier

Attention should be paid to the occurrence of oil leakage on the aluminum alloy lifting platform to avoid secondary damage caused by a shortage of hydraulic oil. Overloading work is prohibited during use

Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented, smooth lifting and low noise.

Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented,Emerod3 meter electric elevator, and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

The verticality of the guide rail frame should meet the requirements of the specifications.


EmerodElectric tatami elevatorOperating procedures for installation and disassembly of lifting equipment



Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

Where to sell API.The L distance depends on the selected wall mount model.

Stop.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

Emerod.To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

The scaffolding of the parking platform should be laid tightly and firmly.