SacramentoSmall electric automatic elevatorApplication field

announcer:hp935HP175192871 release time:2024-03-19 13:55:10

The use of standard section connecting bolts should comply with the user manual and specification requirements.

When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

Sacramento.The working principle of the aluminum alloy lifting platform is that hydraulic oil is composed of a vane pump to form a certain pressure, which enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve,SacramentoFolding electric elevator, and balance valve

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

.Use floor doors and cage door devices on construction sites where conditions permit.

Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator, all components should be inspected, and standard sections and other components with severe wear and deformation should be replaced.

Installation verticality deviation guide rail frame erection height,SacramentoFour wheel electric elevator, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.


SacramentoSmall electric automatic elevatorApplication field



Then the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform, and the lifting of goods should try to maintain a stable and uniform speed.

Is there a relevant rule requirement for the cleanliness of hydraulic stations?

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

Application process.Electric elevators used in various places.

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

A complete lifting platform accessory can be selected and customized according to different places, venues, and environmental usage conditions. Meet the needs of different users. So why lifting platforms can be used and installed in so many industries and places is because they can achieve multi-purpose, demonstrate multifunctional, meet various different needs, and win market demand. In modern industrial transportation processes, docks, warehouses floors, workshops and other places that require rapid loading and unloading of goods, they have played a very practical value, It has also brought great contributions to the entire industry and even the entire economic development. However, and regular maintenance and upkeep are essential. Otherwise, both work efficiency and utilization rate will decrease,SacramentoElectric elevator 8 meters, and at that time, the gains and losses will outweigh the losses.


SacramentoSmall electric automatic elevatorApplication field



The counterweight guide rail should meet the specification requirements.

Sampling inspection.The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

Construction electric elevators should be equipped with lower limit switches that are sensitive and reliable.

Protective measures should comply with regulatory requirements.

Sacramento.Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation, and corrosion of steel wire ropes

Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).