dadIndoor electric elevatorThe basic structure of

announcer:hp935HP175192871 release time:2024-03-07 09:47:26

The setting of the cable guide frame should comply with the user manual and regulatory requirements.

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.

dad.Greater than 0.04s; When the hydraulic buffer is used, the oil level shall be checked, and the action of the hydraulic buffer shall be monitored by the Electrical safety switch. When the hydraulic buffer is compressed the cage shall not

Braking. The brake limit switch for partial motion control of the electric hoist traction machine. Assembly that restricts the operation of the lift car when it is opened to a high or low position; If the limit switch controls the overtravel switch. When the car travels to a high or low position, it will take on the function of raising or lowering. In order to prevent the lift car from crashing or sinking, stage equipment should be dismantled with over travel switches that can cut off power and cannot be automatically reset, and installed in the machine room,dad3 meter high electric elevator, rather than in the shaft; A buffer should be installed that can absorb the energy of the moving mechanism and reduce impact.

.Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Later, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, it should not be used again to avoid accidents, personnel and property losses.


dadIndoor electric elevatorThe basic structure of



When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

8m; When the lifting speed is greater than 0.8m/s, after the upper limit switch is triggered by the hanging cage, the upper small safety distance L should meet the following requirements: L=8+0.1V2, where L is the upper safety distance; V: Increase speed

The L distance depends on the selected wall mount model.

management.The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, all components should be inspected, and standard sections and other components with severe wear and deformation should be replaced.


dadIndoor electric elevatorThe basic structure of



Mechanical devices controlled by cage movement should not be used to open or close the landing door.

how.Remind customers that there are still many areas to pay attention to when maintaining and maintaining the lifting platform. We also hope that customers and friends can pay more attention when using it to ensure the safety of personnel and property, regularly maintain and extend its service life, and create greater benefits for the enterprise. What is the matching degree of electric elevators? Everyone has always been confused. In short, the matching degree of electric elevators is how the height of the electric elevator can be combined with the operating height. Electric elevators are not used frequently, so we must make it clear based on the actual operating height and actual load capacity when using electric elevators. If the frequency is too high, we recommend using a guide rail electric elevator. This type of electric elevator is not easy to malfunction under high-frequency operation which effectively solves the problem of load capacity. If the frequency of use is too high and the height is relatively high, By solving the load capacity and frequency of use, the matching problem of electric elevators is effectively solved. Concept of electric elevator rotary valve: The electric elevator rotary valve is a type of valve that quickly opens and closes, and the rotary valve can reduce oil pipeline channels and optimize line settings.

After the limit switch is activated, only professional personnel can restore the movement of the suspension cage.

Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops

dad.Safety performance: Electric elevators not only have the safety device of traditional traction elevators, but also have an overflow valve to prevent excessive system pressure during upward movement

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

High lifting height, using side mounted oil cylinders,dadAluminum alloy electric elevator, stable operation, noise free, easy maintenance, and longer service life.