Cage wooden boxElectric elevatorEconomic operation

announcer:hp935HP175192871 release time:2024-02-18 09:23:20

The quality of the standard section should comply with the product manual and specification requirements.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Cage wooden box.The suspension cage movement can only be resumed after operator operation.

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

.Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, stability, etc.,Cage wooden box3 meter high electric elevator, and the production should meet the design requirements.

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

When the wall bracket adopts non matching standard products, design calculations should be carried out.


Cage wooden boxElectric elevatorEconomic operation



The quality of the standard section should comply with the product manual and specification requirements.

Setting requirements: Buffers should be installed below the suspension cage and counterweight running channel.

Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods, electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, during the operation of the electric elevator,Cage wooden boxFully self-propelled electric elevator, it may cause the electric elevator to lose balance. After the goods are stacked completely, ropes should be used to lock the goods, so that they are not afraid of the goods during the lifting process; Careless; Scattered down

where.Braking. The brake limit switch for partial motion control of the electric hoist traction machine. Assembly that restricts the operation of the lift car when it is opened to a high or low position; If the limit switch controls the overtravel switch. When the car travels to a high or low position,Cage wooden boxAll electric small elevator, it will take on the function of raising or lowering. In order to prevent the lift car from crashing or sinking stage equipment should be dismantled with over travel switches that can cut off power and cannot be automatically reset, and installed in the machine room, rather than in the shaft; A buffer should be installed that can absorb the energy of the moving mechanism and reduce impact.

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

For customers to use and operate the lifting platform for a long time, the editor briefly introduces how to maintain and repair the lifting platform: First of all, normal maintenance is mainly focused on prevention, especially if any damage or malfunction is detected and corrected or repaired in a timely manner. Careful inspection and maintenance at this time can save costs and avoid larger problems, resulting in costly repairs.


Cage wooden boxElectric elevatorEconomic operation



The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

agent.Principle of electric elevator rotary valve: When the electric elevator rises, the rotary valve will automatically open. To close the plug valve, it is necessary to first turn the handle to turn the plug to a 90 degree position until it is closed, and then turn the transmission handwheel to lower the plug and achieve sealing.

Before installing the construction electric elevator, the foundation should be inspected and approved before installation.

Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

Cage wooden box.There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances, it is allowed to lower the height of the lower door opening, but in any case