Shi qiuqingHousehold elevatorAnalysis of fire rating

announcer:hp530HP141750488 release time:2024-02-09 10:47:10

Before installation, the installation personnel should confirm the infrastructure such as the foundation and shaft, pay attention to alignment, leveling, and confirm that the foundation meets the requirements before construction.

The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects). The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, also known as a hydraulic lock a hydraulic control one-way valve, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure.

Shi qiuqing.A lifting platform is a lifting device that lifts people or goods to a certain height. When vertical conveying is carried out in logistics systems such as factories and automatic warehouses, various flat conveying equipment is often installed on the lifting platform as a connecting device for conveying lines at different heights. Usually driven by hydraulic pressure, it is called a hydraulic lifting platform. In addition to being used for transporting goods at different heights, it is widely used for high-altitude installation, maintenance, and other operations.

Solution: Check if the performance of the legs is good, even if the butter is polished to increase its properties.

. There is air in front of the pilot valve of the elevator overflow valve noise overflow valve. The damping hole on the main valve core of the overflow valve is blocked by oil dirt, and the pilot valve and valve seat are matched without spring deformation or incorrect installation. The remote control port has excessive oil flow, low or high hydraulic oil viscosity, and resonance occurs with components in the circuit. Troubleshooting: Strengthen sealing, repeatedly adjust the pressure, exhaust and clean the valve body several times, Make the damping hole unobstructed, repair or replace the spring, reduce the flow of the remote control port, replace the oil, and other components. The pressure setting of other components should not be similar to the pressure setting of the relief valve. 5. The noise of the elevator pipeline is usually caused by excessive dead bends or loose fixed sleeves in the hydraulic pipeline.

The installation personnel should confirm and count the equipment details, confirm that there are no omissions in the shipped equipment details, check if the tools are complete, and ensure the smooth progress of the installation process.

Regularly check whether each organization is functioning properly and whether there is noise. If problems are found, they should be promptly cleaned up.


Shi qiuqingHousehold elevatorAnalysis of fire rating



The characteristics of the platform include reliable hydraulic system,Shi qiuqingMobile hydraulic lifting platform, simple operation, large load-bearing capacity, and rear hinge support.

Based on the foundation plan, pay attention to alignment, leveling, and alignment to ensure the foundation level and various usage requirements. The access road for external construction elevators should be flat and have sufficient space for equipment parking.

Oil leakage from the oil cylinder: If it is a problem with the sealing ring, replace the sealing ring. If there are debris or debris on the oil cylinder, it is recommended to replace it with a new one.

Sampling inspection.Before installation,Shi qiuqingSmall hydraulic lifting platform, the installation personnel should confirm the infrastructure such as the foundation and shaft, pay attention to alignment, leveling, and confirm that the foundation meets the requirements before construction.

For hydraulic cylinders in hydraulic elevators, it is not practical to change their effective working area A (equivalent to displacement) to adjust the speed. Generally,Shi qiuqingHydraulic lifting platform Electric lifting platform, the speed can only be adjusted by changing the flow rate. For variable displacement motors, speed regulation can change both the flow rate and the motor displacement.

The precautions to consider when selecting a hydraulic lift oil tank include: considering the structure of the oil tank the partition in the traditional oil tank cannot settle dirt. A vertical partition should be installed along the longitudinal axis of the oil tank, with a space left between one end of the partition and the end plate of the oil tank to connect the gaps on both sides of the partition. The inlet and outlet of the hydraulic pump are arranged on both sides of the partition at the disconnected end, so that the distance Z between the inlet and return oil is far, The hydraulic oil tank has more heat dissipation effect.


Shi qiuqingHousehold elevatorAnalysis of fire rating



When the hydraulic lifting platform is working, the load cannot exceed its rated load. When it is raised to a certain height, the larger the mass of the object, the greater the shaking

Application process.Remove the hydraulic oil tank filler cap, filter cover, inspection hole hydraulic oil pipe and other parts to avoid dust when removing the system oil pipe. Clean the disassembled parts before opening them. When disassembling the hydraulic oil tank filler cap, first remove the soil around the tank cap, loosen the tank cap, and remove any remaining debris from the joint (do not rinse with water to prevent water from seeping into the tank). After confirming cleaning, open the tank cap.

When working on the dam crest, steep slopes, cliffs, towers, suspension bridges, and other dangerous edges, safety nets or protective railings should be installed on the side facing the air. Otherwise, workers must use safety belts. Ice, snow, gravel, and soil on the steep slopes of steep cliffs boarding bridges, or sidewalks must be regularly cleaned, and a 1-meter high railing must be installed on the outer side. Install an 18 centimeter high side board or soil ridge on the inner side of the railing to prevent falling objects from injuring people.

Regularly inspect the hydraulic lifting equipment of the upper and lower materials to ensure the safety of the rail type elevator and the safety of the material supply to the rail type lifting platform.

Shi qiuqing.Reason: Manual pump and gear pump have severe oil leakage. Cleaning method: Replace the oil pump sealing ring to clean it. Reason: Gear pump is damaged, The oil pumped out has no pressure. Cleaning method: Replace the gear pump to clean the problem. Reason: Lack of hydraulic oil. Cleaning method: Add enough hydraulic oil to clean the problem. Reason: Circuit open. Cleaning method: Check the button and fuse to clean the problem. Reason: Filter blockage. Cleaning method: Replace or clean the problem. Reason: Support valve or electromagnetic directional valve malfunction. There are two situations: the input voltage of the electromagnetic coil is lack of 220V. The solenoid coil is burnt out and the valve core is stuck. Cleaning method: maintenance or replacement can be used to clean the natural descent of the lifting platform. Reason and cleaning method: one-way valve leakage cleaning method: check the check valve in the valve. Assuming there is dirt on the sealing surface of the check valve. Clean the check valve.

The noise and oil level of the elevator oil cylinder are too low. From the air at the connection of the oil filter or joint to the oil, the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, and the air or oil pipe is on the oil surface, Mixing air into the oil to eliminate: The concentricity should be adjusted to within 0.1MM. The coupling should be repaired or the oil pump should be replaced to increase the oil volume above 400mm in the oil filter and joint positions. The rotating shaft sealing ring should be replaced to clean the oil filter screen, filter the oil, lock the return oil pipeline, and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged, it will cause cavitation under high pressure and cause significant noise. At this point, it is necessary to exhaust the air in a timely manner.

When the hydraulic oil of the equipment is insufficient, it will not cause lifting. At this point, you only need to add enough hydraulic oil to run.