QinghaiCurved arm electric elevatorreliable

announcer:hp935HP175192871 release time:2024-02-07 09:32:55

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Qinghai.Aluminum alloy lifting platforms can be divided into single column aluminum alloy, cargo elevator double column aluminum alloy, three column and four column aluminum alloy. Can be used in factories, automated warehouses, municipal facilities, docks, buildings, and installations

It is understood that the scissor type lifting platform is a widely used specialized equipment for high-altitude operations. Its shear fork mechanical structure provides high stability for the lifting platform, wide working platform, and high load-bearing capacity, making the range of high-altitude operations larger and suitable for multiple people working simultaneously. The lifting power is divided into 24V, diesel engines using Italian and domestic hydraulic pump stations, which have anti slip and the table top is equipped with anti slip insulation buckle plates, insulation,QinghaiSmall hydraulic electric elevator, and safety features. Please rest assured to use.

.Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.


QinghaiCurved arm electric elevatorreliable



When the landing door is closed, the full width of the lifting passage opening should be covered.

The coaxiality between the motor shaft and the worm shaft in the aluminum alloy electric elevator drive device should be less than 0.1mm, and there should be a 2mm gap at the shaft end to ensure that the motor bearings bear reasonable loads and reduce motor operating noise; electric

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.

Honesty is the foundation.Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, which is used to vertically transport items from the ground to a designated location or even the stage plane. The lifting platform of the music pool is often used for transporting movable seats, etc.

Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented, the full width of the lifting passage opening should be covered.

Quality risk.Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends, it can automatically cut off the oil circuit and stop descent

It is strictly prohibited to use travel limit switches as switches to stop operation.

Then, the lifting platform platform platform that carries the load needs to be balanced,Qinghai8 meter electric elevator, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform, and the lifting of goods should try to maintain a stable and uniform speed.

Qinghai.Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.

Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, which is used to vertically transport items from the ground to a designated location or even the stage plane. The lifting platform of the music pool is often used for transporting movable seats, etc.