Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

The foundation base or embedded parts should be fully embedded in the concrete foundation plate.

Frisian.The up travel (limit) switch should be of the automatic reset type.

When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.

.Setting requirements: Before starting work every day and changing shifts,FrisianDedicated electric elevator, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results, and report any problems found to the user unit.

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.


FrisianSimple electric elevatorEconomic operation adjustment work



In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings,FrisianThree phase electric elevator, a half height middle crossbar, and a toe board at least 150mm above the ground.

When a suspension cage with a rated load capacity acts on the buffer at a speed greater than the rated speed of 0.2m/s, the average deceleration of the suspension cage should not exceed 1g, and the time when the peak deceleration exceeds 5g should not exceed

The setting of the cable guide frame should comply with the user manual and regulatory requirements.

Free consultation.The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.

The landing door should meet the requirements of the specifications and achieve standardization.

The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.


FrisianSimple electric elevatorEconomic operation adjustment work



When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

total cost.The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator,FrisianScissor fork electric elevator, with a size of 8 meters by 2 meters.

When a suspension cage with a rated load capacity acts on the buffer at a speed greater than the rated speed of 0.2m/s, the average deceleration of the suspension cage should not exceed 1g, and the time when the peak deceleration exceeds 5g should not exceed

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

Frisian.Advantages of electric elevator rotary valve: Simplify the installation of electric elevator pipelines; The operation is more convenient, and the valve can be opened and closed at any time; The installation of a rotary valve reduces the friction of the sealing components; Compact structure, small size, and space saving; Increased the service life of electric elevator pipelines and solved the problem of easy oil leakage.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

The verticality of the guide rail frame should meet the requirements of the specifications.