AshburnElectric lifting platform 2 metersRapid growth in market size

announcer:hp935HP175192871 release time:2024-01-26 13:17:09

Acceptance: Concrete strength grade C30 strength testing report.

The wall bracket of the construction electric elevator should be intact and reliably fixed, wall bracket spacing and its attachment distance, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

.Acceptance: Concrete strength grade C30, strength testing report.

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

Horizontal lead screw mechanical electricity


AshburnElectric lifting platform 2 metersRapid growth in market size



When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.

When using lifting equipment, the workbench should be kept in a horizontal state.

Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean, and after changing the hydraulic oil, it must be automatically lifted and lowered 2 to 3 times to ensure that the air in the oil cylinder is completely discharged, maintain sufficient space, and ensure that the lifting platform can be lifted to the rated lifting height.

Encyclopedic knowledge.The setting of the cable guide frame should comply with the user manual and regulatory requirements.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.


AshburnElectric lifting platform 2 metersRapid growth in market size



The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements,AshburnElectric small hydraulic elevator, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

. The shutdown device (emergency stop switch) should be installed outside the ground protective fence; b) Pulley room (if any. Pulley room refers to a room where only pulleys or speed limiters and electrical equipment are installed; c) hanging cage top, if

The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve,AshburnElectric small elevator,AshburnSmall and simple electric elevator, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

Ashburn.The verticality of the guide rail frame should meet the requirements of the specifications.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.