The elevator has strong controllability, simple operation, and high accuracy, which can meet different needs of different heights, that is, press and stop, making high-altitude operations simple and feasible.

Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, and then return it to the oil tank and connect the pipeline.

Katanzaro.Features: Made of high-strength and high-quality aluminum alloy material, it has the advantages of beautiful appearance, small volume, smooth lifting, safety and reliability. Its appearance allows for high lifting capacity in extremely small spaces. The column lifting system has the characteristics of large load capacity, strong stability, large platform area, and convenient implementation.

How to maintain the elevator when it is not in use? The editor reminds users that if our elevator is not ready for use for a long time, we must take good care of the equipment when not in use.

.The double masted elevator adopts high-strength and high-quality materials, which have the advantages of beautiful appearance, small size, light weight, balanced lifting, safety and reliability. It is widely used in factories, hotels, restaurants, theaters airports, exhibition halls, and other places. It is a good safety partner for maintenance equipment, painting decoration, changing lighting fixtures, electrical appliances, cleaning and maintenance, and other purposes.

Compact in structure, it is a small lifting platform that can enter narrow passages and elevators.

The hydraulic power unit adopts an integral pump station, with a compact structure and reliable performance.


KatanzaroAutomobile hydraulic lifting platformHow does an enterprise survive and develop



Spare parts are intact and of the same model. Items such as valves and seals should be placed in dry and dust-free packaging. When the maintenance of hydraulic elevators requires entry into the interior of the platform for work, the working surface of the elevator must be fixed or supported firmly by a crane or other equipment after the elevator is lifted before entering the interior of the living platform for work. Before the maintenance of the hydraulic aluminum alloy elevator starts, the tools used must be counted. After the maintenance is completed, and counted to prevent the tools used for maintenance from being left inside the equipment, especially in the distribution box. When repairing the hydraulic system of the elevator, it is necessary to keep the maintenance site clean and dust-free. When repairing the fastening screws of the elevator, it is necessary to press the correct angle first. When tightening screws, use a torque wrench to prevent excessive damage to the screws. After the maintenance is completed and before the power on test, it is necessary to count the number of maintenance personnel to ensure that there is no one inside the elevator. This is very necessary for the maintenance of large fixed hydraulic elevators. After counting the number of people inspecting and repairing the equipment and the maintenance site, the power transmission test can only be carried out. After the elevator maintenance is completed, the equipment maintenance record must be filled out, which should include the equipment maintenance date, personnel participating in the maintenance, maintenance items, brand, model and specification of replaced parts, maintenance effect, and whether the equipment still has problems after the maintenance is completed.

Overvoltage, undervoltage, and phase fault protection. Overvoltage, undervoltage, and phase fault protection devices operate when there is a voltage drop, overvoltage, or phase fault or phase fault in the electrical circuit, and the construction elevator stops running. Some construction elevator maintenance personnel on construction sites do not promptly eliminate the malfunction of the overvoltage, undervoltage, and phase fault protection device, but instead cancel or short-circuit the protection device to make it ineffective,KatanzaroHydraulic elevator lifting platform, leaving a hidden danger of accidents for the equipment. Some early products do not have this protection device at all, and it is recommended to equip it. The construction elevator should be able to carry people and objects only when the overvoltage, undervoltage, and phase fault protection devices are reliable and effective.

Driving under the influence of alcohol is strictly prohibited, and ongoing high-altitude operations should also be terminated if feeling unwell.

High quality brand.Elevators play an important role in handling,KatanzaroPush-pull hydraulic lifting platform, construction, and other operations, providing convenient transportation equipment. More and more elevators are being put into use in the market but unstable voltage can have a certain impact on elevators during use.

The garage door should be opened or the exhaust device should be opened. So that the exhaust gas can be stored in the garage at any time. Even if working outdoors. Also, do not stay near the exhaust pipe of the working engine for a long time.

Remove and disassemble the lowering valve, blow the valve core clean with compressed air, and then reinstall it.


KatanzaroAutomobile hydraulic lifting platformHow does an enterprise survive and develop



A type of elevator equipment consisting of a walking mechanism, hydraulic mechanism, electric mechanism,KatanzaroElectric hydraulic lifting platform, and support mechanism. The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge.

Quality documents.Two sets of masts support the synchronous lifting of the working platform, and the elevator has stable operation; The overall lifting guardrail device has good strength and greatly reduces the height of the entire machine during transportation. It is very convenient for loading and unloading, and can be assembled or disassembled in one lift; Can be equipped with gantry cross frames; Having the same convenient maneuverability as a single mast, the support structure is the same as a single mast platform; It has good load-bearing capacity and is suitable for no more than two people climbing at the same time.

Electrical part: It consists of power, signal, safety, and lighting devices.

The double protection leg structure ensures safer work and can be used for lifting and lowering operations close to the working face.

Katanzaro.Hydraulic lifting platforms are widely used in factory maintenance, municipal construction, and decoration of hotels in industrial and mining enterprises, with reliable quality and perfect performance.

The guardrail structure is integral and collectible, the tools used must be counted. After the maintenance is completed the working surface of the elevator must be fixed or supported firmly by a crane or other equipment after the elevator is lifted before entering the interior of the living platform for work. Before the maintenance of the hydraulic aluminum alloy elevator starts, the tools should be classified and organized, and counted to prevent the tools used for maintenance from being left inside the equipment, especially in the distribution box. When repairing the hydraulic system of the elevator, it is necessary to keep the maintenance site clean and dust-free. When repairing the fastening screws of the elevator, it is necessary to press the correct angle first. When tightening screws, use a torque wrench to prevent excessive damage to the screws. After the maintenance is completed and before the power on test, it is necessary to count the number of maintenance personnel to ensure that there is no one inside the elevator. This is very necessary for the maintenance of large fixed hydraulic elevators. After counting the number of people, inspecting and repairing the equipment and the maintenance site, the equipment maintenance record must be filled out, which should include the equipment maintenance date, personnel participating in the maintenance, maintenance items, brand model and specification of replaced parts, maintenance effect, and whether the equipment still has problems after the maintenance is completed.