MILUSHydraulic lifting platform cargo elevatorChemical composition

announcer:hp695HP135175170 release time:2024-05-09 19:41:10

The daily maintenance of guide rail type cargo elevators should ensure that the transmission position where the grease nipple is located needs to be lubricated twice a month. For areas where grease cannot be added, it is necessary to clear the oil circuit or replace the grease nipple until butter can be added. Otherwise,MILUSStraight top hydraulic lifting platform, it is prohibited to use the equipment.

Check the hydraulic oil quality and level. When the lifting platform is raised to a high position, the hydraulic oil level should be 40-50 millimeters higher than the bottom of the oil tank. When the color of the hydraulic oil darkens the oil becomes sticky, or there are foreign objects such as gravel in the oil, the hydraulic oil should be replaced in a timely manner. The hydraulic system of the lifting platform should be checked for hydraulic and pipeline connections. If the pipeline is damaged, it should be replaced immediately; When there is looseness in the connection part, tighten the pipe joint.

MILUS.Walking: assisted self-propelled, two wheel traction, self driving, and car modification. Professional scissor lift manufacturer with quality assurance professionalism, timely supply, and high cost-effectiveness has become the preferred brand for many wire products. Welcome to purchase!

Good stability: The overflow valve can prevent excessive system pressure during upward movement. Emergency manual valve: In case of power failure, it can cause the elevator car to descend to the nearest floor position and open the door. Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position; Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops.

.Installing bearings for elevators may seem simple, but it is also important to pay attention to some details, such as: it is actually difficult to thrust bearings into the shaft pins when excessively installing them. However, sometimes, some people may think of using a hammer to hammer the bearings for convenience, and use brute force during installation. In fact, directly hitting the bearings with a hammer can cause significant damage to the bearings, which is the main reason for bearing damage and reducing the service life of the bearings. So when installing bearings, we must not go too far. Fortunately, we can place some soft cloth or cardboard on top of them before installing them.

Maintain a smooth access road for external construction elevators and sufficient parking space for equipment. When using a crane for auxiliary installation, full consideration should be given to whether the on-site environment meets the operating conditions of the crane.

The lifting platform has been inspected and debugged before leaving the factory, and all technical indicators meet the design requirements. When in use, only the power supply needs to be connected and the hydraulic and electrical systems basically do not need to be adjusted.


MILUSHydraulic lifting platform cargo elevatorChemical composition



Do not adjust the solenoid valve on the motor arbitrarily. The solenoid valve is pre adjusted before leaving the factory, and random adjustment can easily cause internal pressure to increase or decrease. In severe cases,MILUSMobile hydraulic lifting table supply, it can shorten the service life of the motor.

Adjust the lowering speed valve for misalignment. If the adjustment is ineffective,MILUSCustomization of hydraulic lifting platform, replace the valve with a new one. Professional manufacturer of scissor lift lifts for quality assurance. The promotional activity is ongoing, and new and old customers are welcome to come for consultation

Operating cost advantage: Low failure rate. Due to the use of advanced hydraulic systems and good methods, the failure rate of elevator operation can be minimized. Low power consumption: When the hydraulic elevator descends, it is driven by the pressure generated by its own weight, which greatly saves energy.

Standard requirements.The seat belt needs to be inspected every six months, with a load of 225 kilograms. The test time is five minutes. After the test, check whether the seat belt is broken or deformed, and daily cleaning work should be carried out. Dust and debris on the motor should be cleaned in a timely manner.

Firstly, it is necessary to use and operate the elevator correctly. The operators should receive systematic operation training: regular inspection of operating standards should be conducted, and any violations of the elevator operation should be punished immediately. In severe cases, they should be transferred from this position. Since the passing of


MILUSHydraulic lifting platform cargo elevatorChemical composition



There are foreign objects inside the oil delivery pipe of the hydraulic lifting platform, which can cause uneven force distribution during the delivery of hydraulic oil, resulting in uneven surface conditions. It is recommended to carefully check whether the delivery pipe is smooth.

Quotation sheet.The surface of each part of the brush should be kept clean, including: scissor lift manufacturers

Dirty normally closed valve; The solution is to remove the normally closed valve and use cleaning agent or cleaning. Long term scissor fork lift manufacturers have a complete range of products, excellent quality, and discounted prices

When encountering overheating in the hydraulic elevator motor, it is necessary to stop it in a timely manner, the electric leakage switch meets the requirements for construction elevators. If the fixed elevator installed is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

The guide rail type cargo elevator has been inspected and debugged before leaving the factory, and all technical indicators have met the design requirements. When in use, only the power supply needs to be connected, and the hydraulic and electrical systems do not need to be adjusted.

Regularly check the connection of each part of the hydraulic elevator, and tighten it if there is any looseness. The tightness of the body connecting bolts should be checked when the body is under pressure, and all connecting shafts must have split pins and be sufficient.