Le HavreThree phase electric elevatorReturn to stability

announcer:hp935HP175192871 release time:2024-01-13 10:55:18

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Work is essential,Le HavreScissor fork electric lifting table, and the main protective accessories include safety belts, guardrails, protective covers, platforms and stairs etc.

Le Havre.Folding arm electric elevators are mostly driven by hydraulic means, and the source of power for the hydraulic system is hydraulic oil. Only when the hydraulic oil quantity is sufficient and the oil quality is high, can the folding arm electric elevator provide greater torque output, thereby improving work efficiency. So, how can we determine whether the newly added hydraulic oil quantity is sufficient? What is the hydraulic oil quantity standard?

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

.The quality of the standard section should comply with the product manual and specification requirements.

Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, and oil cylinder once a week to avoid dust and debris affecting normal operation.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.


Le HavreThree phase electric elevatorReturn to stability



Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil,Le HavreElectric elevator 8 meters, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring,Le HavreElectric hydraulic elevator 15 meters, and oil cylinder once a week to avoid dust and debris affecting normal operation.

Is there a relevant rule requirement for the cleanliness of hydraulic stations?

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

Trustworthy.It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations making high-altitude operations easier

Vertical lead screw electric lifting mechanism: Adopting a lead screw transmission method, and different steps can be formed within the travel range to meet the needs of meetings and performances; Pavilion, Terrace, Tower Pavilion; Ideal props.

Then, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform, and the lifting of goods should try to maintain a stable and uniform speed.


Le HavreThree phase electric elevatorReturn to stability



The use of standard section connecting bolts should comply with the user manual and specification requirements.

The cost is reasonable.Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, family dormitories, and

8m; When the lifting speed is greater than 0.8m/s, after the upper limit switch is triggered by the hanging cage, the upper small safety distance L should meet the following requirements: L=8+0.1V2, where L is the upper safety distance; V: Increase speed

The setting of the cable guide frame should comply with the user manual and regulatory requirements.

Le Havre.There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology, smooth lifting and low noise.