LexlipElectric elevators for construction sitesWhat maintenance is needed on weekdays

announcer:hp935HP175192871 release time:2023-12-26 10:48:51

The quality of the standard section should comply with the product manual and specification requirements.

Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

Lexlip.The body in the lateral adjustment device of the driving plate should ensure a compressed state, so that the gear has a certain radial constraint, and ensure that the gear and rack always mesh well throughout the entire operation.

Construction electric elevators outside the lightning protection range

.High lifting height, using side mounted oil cylinders, stable operation, noise free easy maintenance, and longer service life.

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Electric elevators used in various places.


LexlipElectric elevators for construction sitesWhat maintenance is needed on weekdays



The setting of the cable guide frame should comply with the user manual and regulatory requirements.

Setting requirements: A limit switch should be set at both the upper and lower ends of the stroke, so that the suspension cage can stop

Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Quality assurance.Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.


LexlipElectric elevators for construction sitesWhat maintenance is needed on weekdays



The landing door should meet the requirements of the specifications and achieve standardization.

supply.With the continuous improvement of urbanization level in China, the number of high-rise buildings in urban areas has sharply increased, and the height of buildings has also continued to grow. This has created a demand for high-altitude lifting platform vehicles. Therefore, in order to meet the needs of the domestic market and the public, efforts will inevitably be made to design and produce high-altitude lifting platform vehicles.

The noise of aluminum alloy electric elevators during operation is relatively low. If the noise is high, it is abnormal. Therefore,LexlipElectric clothes drying elevator, it is necessary to do a good job in troubleshooting, find the cause in a timely manner, reduce noise pollution, and reduce dangerous accidents

The net height of the landing door opening should not be less than 8m and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed,Lexlip200 kg portable electric elevator, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts,LexlipSmall electric elevator platform, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

Lexlip.Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), family dormitories, and

Implementing multiple shifts of homework should fill in and submit records according to regulations.