AntwerpSmall hydraulic electric elevatorMaintain a decline close to zero

announcer:hp935HP175192871 release time:2023-12-23 09:36:50

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

In order to meet the needs of contemporary audiences and achieve perfect effects, in addition to lighting and sound stage machinery is particularly important on the stage. On the stage, there are suspension rods, suspension points, lighting bridges, lighting suspension cages, and fire curtains. Under the stage, there are lifting platforms, car platforms, turntables, and lifting orchestras. Some lifting platforms are equipped with turntables, or there are lifting platforms in the turntables. Various types of lifting platforms are equipped in professional opera houses, dance theaters,AntwerpTwo phase electric elevator, and many internationally renowned music halls. It has the functions of quickly changing scenery, meeting the needs of stage design and choreographers, creating special atmosphere and effects and changing the stage form according to the needs of the performance.

Antwerp.When a single steel wire rope is excessively stretched, the Electrical safety device shall stop the operation of the electric lift.

High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

.Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results, stable operation using side mounted oil cylinders, noise free, easy maintenance, and longer service life.

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.


AntwerpSmall hydraulic electric elevatorMaintain a decline close to zero



Safety performance: Electric elevators not only have the safety device of traditional traction elevators, but also have an overflow valve to prevent excessive system pressure during upward movement

The cargo is 0.5m.

Installation verticality deviation guide rail frame erection height, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

Energy costs.Acceptance: Concrete strength grade C30, strength testing report.

Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, which is used to vertically transport items from the ground to a designated location or even the stage plane. The lifting platform of the music pool is often used for transporting movable seats, etc.

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.


AntwerpSmall hydraulic electric elevatorMaintain a decline close to zero



Setting requirements: The landing door should be standardized and tooled.

Market trend.The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.

Folding arm electric elevators are mostly driven by hydraulic means, and the source of power for the hydraulic system is hydraulic oil. Only when the hydraulic oil quantity is sufficient and the oil quality is high, can the folding arm electric elevator provide greater torque output, thereby improving work efficiency. So, how can we determine whether the newly added hydraulic oil quantity is sufficient? What is the hydraulic oil quantity standard?

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

Antwerp.Safety performance: Electric elevators not only have the safety device of traditional traction elevators,AntwerpElectric brick elevator on construction site, but also have an overflow valve to prevent excessive system pressure during upward movement

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.