UlmPlatform electric elevatorbrand

announcer:hp935HP175192871 release time:2023-12-18 12:46:11

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

The use of standard section connecting bolts should comply with the user manual and specification requirements.

Ulm.8m; When the lifting speed is greater than 0.8m/s, after the upper limit switch is triggered by the hanging cage, the upper small safety distance L should meet the following requirements: L=8+0.1V2, where L is the upper safety distance; V: Increase speed

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

.When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.

As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load,Ulm6 meter high electric elevator, can achieve multiple points, and can be controlled up and down floors to achieve safe use.


UlmPlatform electric elevatorbrand



The function of the lifting platform in a theater is roughly as follows: the main lifting platform arranged in the main performance area of the stage is mainly used to quickly change the scenery. Typically, with&quo; Product; In the music and dance theater stage arranged in a zigzag pattern, the lifting platform, side car platform and rear car turntable perform a rapid transformation of the entire or partial scene. This arrangement allows for rapid switching of three full sets.

Only after the operation of professional personnel can the suspension cage movement be restored.

According to the needs of different performance genres, the form of the stage can be changed. For example using an orchestra pit lift can combine a framed stage with a large lip or even an extended stage. In an experimental theater, using a lift can make the theater have various forms such as an end stage, an extended stage, an intermediate stage, a T-shaped stage, or a hall.

Installation works.Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.

As a material loading and unloading equipment recognized by customers in the lifting platform,UlmElectric belt elevator,UlmElectric hydraulic elevator 15 meters, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.


UlmPlatform electric elevatorbrand



Especially suitable for steel structured factories, the full width of the lifting passage opening should be covered.

Folding arm electric elevators are mostly driven by hydraulic means, and the source of power for the hydraulic system is hydraulic oil. Only when the hydraulic oil quantity is sufficient and the oil quality is high can the folding arm electric elevator provide greater torque output, thereby improving work efficiency. So, how can we determine whether the newly added hydraulic oil quantity is sufficient? What is the hydraulic oil quantity standard?

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Ulm.The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean, and after changing the hydraulic oil, maintain sufficient space, and ensure that the lifting platform can be lifted to the rated lifting height.