Toulon200 kg portable electric elevatorbrand

announcer:hp935HP175192871 release time:2023-11-11 23:42:16

Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, and

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Toulon.The down travel (limit) switch should be of the automatic reset type.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

.There is no need to set up a computer room above the shaft like an elevator and the top floor height can be installed at least 2.5 meters.

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

When the foundation is set on the roof or floor structure the bearing capacity of its supporting structure should be checked.


Toulon200 kg portable electric elevatorbrand



When the landing door is closed,ToulonSmall electric loading elevator, the full width of the lifting passage opening should be covered.

And the decoration team is also using aluminum alloy electric elevators. What safety considerations should we consider during the use process? Many manufacturers have not clearly indicated it. Today, the mechanical editor will talk to you about aluminum alloys

From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machinery

Quality inspection report.To meet the needs of stage craftsmanship and layout; Product; In the music and dance theater stage arranged in a zigzag pattern, auxiliary lifting platforms are often arranged in front, back, left, and right of the main stage lifting platform. The side and rear auxiliary lifting platforms are used for the smooth opening of the side platform and rear vehicle turntable, while the front auxiliary lifting platform is used to place the rear vehicle turntable near the platform entrance. The leveling lifting platform below the side platform and rear vehicle turntable can be used to level the platform after the side platform or rear vehicle turntable is driven out, so that the entire platform does not have a height difference,ToulonLEGO Electric Elevator, ensuring the safety of the cast members.

From the above comparison,Toulon12 meter electric elevator, it can be seen that hydraulic electric lifting mechanisms have stable lifting, low noise, long service life, large load bearing capacity, and are relatively simple, making them suitable for use in stage equipment.

From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machinery


Toulon200 kg portable electric elevatorbrand



Then, the lifting platform platform platform that carries the load needs to be balanced, and the lifting of goods should try to maintain a stable and uniform speed.

Variable cost.When the wall bracket adopts non matching standard products, design calculations should be carried out.

Equal effect.

The counterweight guide rail should meet the specification requirements.

Toulon.The use of standard section connecting bolts should comply with the user manual and specification requirements.

Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.