SeksadIndoor small electric elevatorHow to check before use

announcer:hp935HP175192871 release time:2023-11-07 16:13:05

suitable for both indoor and outdoor installation.

Seksad.Lowering platform, vehicle mounted lifting platform, self-propelled lifting platform, diesel engine curved arm self-propelled lifting platform, folding arm lifting platform, cylinder sleeve lifting platform, aluminum alloy lifting platform, and special

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm,Seksad500kg electric elevator, the size of any through-hole and opening related to the distance between any door and adjacent moving parts as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

.When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Horizontal lead screw mechanical electricity

It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easier


SeksadIndoor small electric elevatorHow to check before use



Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.

When the landing door is closed, the full width of the lifting passage opening should be covered.

A complete range of products.When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.

When the foundation is set on the roof or floor structure the bearing capacity of its supporting structure should be checked.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.


SeksadIndoor small electric elevatorHow to check before use



The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Inspection standard.When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements,Seksad24 volt electric elevator, but safety should be maintained.

Construction electric elevators should be equipped with travel limit switches, as follows: automatic reset type upper and lower limit switches should be installed on construction electric elevators,SeksadElevator electric platform, but the upper and lower limit switches should not be triggered as high

Setting requirements: The installation and dismantling workers, electricians, and other operators of construction electric elevators should have special construction operations.

Seksad.The function of the lifting platform in a theater is roughly as follows: the main lifting platform arranged in the main performance area of the stage is mainly used to quickly change the scenery. Typically, the lifting platform, side car platform, and rear car turntable perform a rapid transformation of the entire or partial scene. This arrangement allows for rapid switching of three full sets.

The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, the landing door shall not be opened.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.