BisegliSubminiature electric elevatorHow to take measures to localize

announcer:hp935HP175192871 release time:2024-09-01 18:17:24

When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

Then, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform,Bisegli3 meter small electric elevator, and the lifting of goods should try to maintain a stable and uniform speed.

Bisegli.Pole

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

.During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise,Bisegli6-meter electric elevator, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

The setting of the cable guide frame should comply with the user manual and regulatory requirements.

Setting requirements: The landing door should be standardized and tooled.


BisegliSubminiature electric elevatorHow to take measures to localize



The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

Degrees, m/s.

Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors,BisegliElectric elevator battery, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.

Affordable price.The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends, it can automatically cut off the oil circuit and stop descent

Work is essential, and the main protective accessories include safety belts, guardrails, protective covers, platforms and stairs etc.


BisegliSubminiature electric elevatorHow to take measures to localize



The landing door should meet the requirements of the specifications and achieve standardization.

Quality inspection report.Stage equipment safety door. To prevent personnel from extending their heads, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

If the set screw is loose, be sure to pin it tightly to prevent accidents caused by the shaft pin falling off. Hydraulic oil should be kept clean and replaced every 6 months.

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

Bisegli.The pump body adopts an integrated pump station, all equipped with imported high-quality pump stations, which must open towards the landing platform side and the door bolt must be set on the side next to the construction electric elevator.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.