Ireland24 volt electric elevatorAfter the holiday, the price of resuming blast furnace production remained stable and sorted out

announcer:hp935HP175192871 release time:2024-06-19 15:43:43

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

Ireland.Afterwards, it should be scrapped.

The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design,IrelandScissor fork electric elevator, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

.Later, when there is a major malfunction of the lifting platform, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, it should not be used again to avoid accidents personnel and property losses.

Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.


Ireland24 volt electric elevatorAfter the holiday, and do not lift until the four legs are firmly supported.<p>The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.<p>Create brilliance.Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.<p>Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.<p>The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.<p></p><p><br/></p><p><p><img src=



Advantages of electric elevator rotary valve: Simplify the installation of electric elevator pipelines; The operation is more convenient,IrelandElevator manufacturer's electric elevator, small size,IrelandElectric scissor type lifting platform, and space saving; Increased the service life of electric elevator pipelines and solved the problem of easy oil leakage.

Process inspection.Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods, the operating failure rate can be reduced to a low level.

Check whether the sealing of components such as the oil cylinder, oil pipe, and motor of the aluminum alloy electric elevator is good and whether there is any air leakage.

The scaffolding of the parking platform should be laid tightly and firmly.

Ireland.Installation and dismantling personnel and drivers should hold certificates to work.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.