ArlingtonElectric basket elevatorShow space of strength

announcer:hp935HP175192871 release time:2024-06-19 13:14:57

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, and the landing doors should function properly.

Arlington.Non automatic reset upper and lower limit switches should be installed at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers),

High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance and longer service life.

.Construction electric elevators outside the lightning protection range

Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods, the operating failure rate can be reduced to a low level.

When the wall bracket adopts non matching standard products, design calculations should be carried out.


ArlingtonElectric basket elevatorShow space of strength



The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

When a suspension cage with a rated load capacity acts on the buffer at a speed greater than the rated speed of 0.2m/s,Arlington6m electric elevator, the average deceleration of the suspension cage should not exceed 1g, and the time when the peak deceleration exceeds 5g should not exceed

When the wall bracket adopts non matching standard products, the protective measures taken should comply with the specification requirements.

When the door is closed,ArlingtonLEGO Electric Elevator, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

The setting of the cable guide frame should comply with the user manual and regulatory requirements.


ArlingtonElectric basket elevatorShow space of strength



The setting of the cable guide frame should comply with the user manual and regulatory requirements.

Where to sell API.When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

The stopper bearing of the mechanism is kept intact.

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

Arlington.Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Use floor doors and cage door devices on construction sites where conditions permit.

Vertical lead screw electric lifting mechanism: Adopting a lead screw transmission method, it can achieve the lifting of a double-layer tabletop. Multiple lifting platforms can be formed as needed, and different steps can be formed within the travel range to meet the needs of meetings and performances; Pavilion, Terrace, Tower, Pavilion; Ideal props.