NuoElectric brick elevatorIndustry price policy

announcer:hp935HP175192871 release time:2024-05-26 17:31:43

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station,NuoElectric three wheel car lift, and the landing doors should function properly.

Nuo.Attention should be paid to the occurrence of oil leakage on the aluminum alloy lifting platform to avoid secondary damage caused by a shortage of hydraulic oil. Overloading work is prohibited during use

Work is essential and the main protective accessories include safety belts, guardrails, protective covers,NuoElectric elevator 200kg, platforms and stairs, etc.

.Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods,NuoElectric light lift, electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, it may cause the electric elevator to lose balance. After the goods are stacked completely, ropes should be used to lock the goods, so that they are not afraid of the goods during the lifting process; Careless; Scattered down


NuoElectric brick elevatorIndustry price policy



Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

The up travel (limit) switch should be of the automatic reset type.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Home page recommendation.Safety performance: Electric elevators not only have the safety device of traditional traction elevators, but also have an overflow valve to prevent excessive system pressure during upward movement

The verticality of the guide rail frame should meet the requirements of the specifications.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.


NuoElectric brick elevatorIndustry price policy



The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver the landing door shall not be opened.

Discount.During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

The top of the hanging cage is accessible; d) During installation/disassembly/maintenance/inspection of the device; e) Inside the hanging cage.

Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, concealed engineering acceptance form, and concrete strength report.

Nuo.Mechanical devices controlled by cage movement should not be used to open or close the landing door.

During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.