Huozhou10 meter electric elevatorWhat

announcer:hp935HP175192871 release time:2024-04-19 10:45:25

a hydraulic control one-way valve

To ensure safe and reliable braking of the lifting platform and prevent accidents, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease,HuozhouElectric boom elevator,HuozhouElectric cargo elevator, and the top floor height can be installed at least 2.5 meters.

Huozhou.Degrees, m/s.

The entrance of each landing platform must be equipped with a landing door,HuozhouElectric high-altitude elevator, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

.When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Setting requirements: The wall bracket should use the manufacturer's matching standard products.


Huozhou10 meter electric elevatorWhat



Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.

Non automatic reset upper and lower limit switches should be installed at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers),

Principle of electric elevator rotary valve: When the electric elevator rises, the rotary valve will automatically open. To close the plug valve, it is necessary to first turn the handle to turn the plug to a 90 degree position until it is closed, and then turn the transmission handwheel to lower the plug and achieve sealing.

Quotation sheet.Installation verticality deviation guide rail frame erection height, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.


Huozhou10 meter electric elevatorWhat



As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.

Design brand.Construction electric elevators outside the lightning protection range

Is the water cooling and air cooling of the hydraulic station the same?

Secondly, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Huozhou.The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

The scaffolding of the parking platform should be laid tightly and firmly.

When the landing door is closed, the full width of the lifting passage opening should be covered.