HardenbachIndoor small electric elevatorEveryone see

announcer:hp935HP175192871 release time:2024-03-30 09:50:52

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, concealed engineering acceptance form, and concrete strength report.

Hardenbach.If the set screw is loose, be sure to pin it tightly to prevent accidents caused by the shaft pin falling off. Hydraulic oil should be kept clean and replaced every 6 months.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

.As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering,HardenbachThree phase electric elevator, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

The pump body adopts an integrated pump station,HardenbachSmall electric automatic elevator, all equipped with imported high-quality pump stations, which can also be selected according to customer requirements to meet customer ideal requirements.


HardenbachIndoor small electric elevatorEveryone see



There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

Do not move after lifting, and do not lift until the four legs are firmly supported.

In addition to ground protective fences, a half height middle crossbar,HardenbachAluminum alloy electric elevator, suitable for both indoor and outdoor installation.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.


HardenbachIndoor small electric elevatorEveryone see



The L distance depends on the selected wall mount model.

technological innovation.Setting requirements: Before starting work every day and changing shifts, record the inspection results, and report any problems found to the user unit.

Before use, we should observe whether there is any damage to the electric elevator. We can conduct a no-load test to raise and lower it. If there are any damaged parts, they should be replaced in a timely manner to prevent major accidents.

Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness strength, stability, etc., and the production should meet the design requirements.

Hardenbach.In order to meet the needs of contemporary audiences and achieve perfect effects, in addition to lighting and sound, stage machinery is particularly important on the stage. On the stage, there are suspension rods, suspension points, lighting bridges, lighting suspension cages, and fire curtains. Under the stage, there are lifting platforms, car platforms, turntables, and lifting orchestras. Some lifting platforms are equipped with turntables, or there are lifting platforms in the turntables. Various types of lifting platforms are equipped in professional opera houses dance theaters, drama theaters, and many internationally renowned music halls. It has the functions of quickly changing scenery, meeting the needs of stage craft layout, meeting the needs of stage design and choreographers, creating special atmosphere and effects, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

When the wall bracket adopts non matching standard products, design calculations should be carried out.