JinghaiFire electric elevatorWhat should be paid attention to when using

announcer:hp935HP175192871 release time:2024-02-25 10:49:46

From the perspective of the safety performance of the machinery itself,Jinghai22ov electric elevator, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machinery

Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

Jinghai.The usual operation of landing and docking.

Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

.The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

Spiral electric lifting mechanism: With all the functions of a regular lifting platform, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise,JinghaiElectric guide rail elevator, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.


JinghaiFire electric elevatorWhat should be paid attention to when using



The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.

Construction electric elevators should be equipped with travel limit switches as follows: automatic reset type upper and lower limit switches should be installed on construction electric elevators, but the upper and lower limit switches should not be triggered as high

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

How much does it cost?.After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

During the use period,Jinghai12 meter electric elevator, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.

The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.


JinghaiFire electric elevatorWhat should be paid attention to when using



When the landing door is closed, the full width of the lifting passage opening should be covered.

Variable cost.The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

The magnetic directional valve returns to the fuel tank. To ensure stable landing of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the landing speed does not change due to heavy objects. It is adjusted by the saving valve

Principle of electric elevator rotary valve: When the electric elevator rises, the rotary valve will automatically open. To close the plug valve, it is necessary to first turn the handle to turn the plug to a 90 degree position until it is closed, and then turn the transmission handwheel to lower the plug and achieve sealing.

Jinghai.The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.