GyrusMobile electric elevatorPoor maintenance will cause trouble

announcer:hp935HP175192871 release time:2024-02-21 12:36:15

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Gyrus.Lowering platform, vehicle mounted lifting platform, self-propelled lifting platform, diesel engine curved arm self-propelled lifting platform, folding arm lifting platform, cylinder sleeve lifting platform, and special

The use of a lifting platform as a tool for storing performance blankets, soft scenery,GyrusFully electric self-propelled elevator, etc. In some theaters,GyrusElectric six meter elevator, there is a soft scenery storage lifting platform located at an appropriate location on the stage for the storage of blankets, soft scenery, etc.

.Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form concealed engineering acceptance form, and concrete strength report.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops


GyrusMobile electric elevatorPoor maintenance will cause trouble



When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

8m; When the lifting speed is greater than 0.8m/s, after the upper limit switch is triggered by the hanging cage, where L is the upper safety distance; V: Increase speed

Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

Excellent service.The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

The setting of the cable guide frame should comply with the user manual and regulatory requirements.


GyrusMobile electric elevatorPoor maintenance will cause trouble



Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

Total quality management.The quality of the standard section should comply with the product manual and specification requirements.

Folding arm electric elevators are mostly driven by hydraulic means, and the source of power for the hydraulic system is hydraulic oil. Only when the hydraulic oil quantity is sufficient and the oil quality is high, can the folding arm electric elevator provide greater torque output,GyrusElectric high-altitude elevator, how can we determine whether the newly added hydraulic oil quantity is sufficient? What is the hydraulic oil quantity standard?

Safety performance: Electric elevators not only have the safety device of traditional traction elevators, but also have an overflow valve to prevent excessive system pressure during upward movement

Gyrus.When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator, all components should be inspected, and standard sections and other components with severe wear and deformation should be replaced.

From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting low noise, large load bearing capacity long service life, and are relatively simple, making them suitable for use in stage equipment.