TrierBasement electric elevatorAcoustic biological effects

announcer:hp935HP175192871 release time:2024-02-18 09:31:06

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Trier.High altitude operations and maintenance in areas such as repair, logistics, electricity, transportation, petroleum, chemical, hotel, mining, and enterprise. The lifting system of the lifting platform is driven by hydraulic pressure,Trier6-meter electric elevator,TrierElectric boom elevator, also known as hydraulic lifting

Vertical lead screw electric lifting mechanism: Adopting a lead screw transmission method it can achieve the lifting of a double-layer tabletop. Multiple lifting platforms can be formed as needed, and different steps can be formed within the travel range to meet the needs of meetings and performances; Pavilion, Terrace, Tower, Pavilion; Ideal props.

.The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position

It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easier


TrierBasement electric elevatorAcoustic biological effects



Before installation, the installation unit should confirm that the foundation, foundation bearing capacity,TrierHigh altitude electric elevator, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, concealed engineering acceptance form, and concrete strength report.

The shutdown device (emergency stop switch) should be non automatic reset type.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Quality inspection report.Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.


TrierBasement electric elevatorAcoustic biological effects



Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Promotion.The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

Construction electric elevators must be equipped with lifting cages and reusable buffers, and comply with regulatory requirements.

The counterweight guide rail should meet the specification requirements.

Trier.The use of standard section connecting bolts should comply with the user manual and specification requirements.

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.