Dortmund200 kg portable electric elevatorBlack momentum weakens and price increases are not sustainable

announcer:hp935HP175192871 release time:2024-02-13 13:11:44

DortmundElectric elevators for elderly care,

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

Dortmund.Stop the suspension cage.

After the electric elevator passes the inspection,DortmundElectric folding elevator, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

.Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), family dormitories,DortmundFixed electric elevator, and

Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation, and corrosion of steel wire ropes

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.


Dortmund200 kg portable electric elevatorBlack momentum weakens and price increases are not sustainable



Principle of electric elevator rotary valve: When the electric elevator rises, the rotary valve will automatically open. To close the plug valve, it is necessary to first turn the handle to turn the plug to a 90 degree position until it is closed, and then turn the transmission handwheel to lower the plug and achieve sealing.

Non automatic reset upper and lower limit switches should be installed at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers),

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Statistics.When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements and record the inspection results.

Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.


Dortmund200 kg portable electric elevatorBlack momentum weakens and price increases are not sustainable



The setting of the cable guide frame should comply with the user manual and regulatory requirements.

offer.Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, family dormitories, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.

Work is essential, and the main protective accessories include safety belts, guardrails, protective covers, platforms and stairs etc.