SacramentoElectric clothes drying elevatorPrices are rising

announcer:hp935HP175192871 release time:2024-02-04 11:29:26

Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented, and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean, and after changing the hydraulic oil, it must be automatically lifted and lowered 2 to 3 times to ensure that the air in the oil cylinder is completely discharged, maintain sufficient space, and ensure that the lifting platform can be lifted to the rated lifting height.

Sacramento.Mobile electric elevators are divided into: four wheel mobile lifting platform, two wheel traction lifting platform, car modified lifting platform manual lifting platform, manual lifting platform, and AC/DC dual purpose lifting platform

In addition to ground protective fences, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar,Sacramento3 meter high electric elevator, and a toe board at least 150mm above the ground.

.After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting,SacramentoZoomlion Electric Elevator, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator,SacramentoElectric elevator, all components should be inspected, and standard sections and other components with severe wear and deformation should be replaced.

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.


SacramentoElectric clothes drying elevatorPrices are rising



There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

In addition, when adding hydraulic oil, it is necessary to ensure the quality of the hydraulic oil, but also affects the working efficiency of folding arm electric elevators due to deterioration issues.

Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.

Safety production.Braking. The brake limit switch for partial motion control of the electric hoist traction machine. Assembly that restricts the operation of the lift car when it is opened to a high or low position; If the limit switch controls the overtravel switch. When the car travels to a high or low position, it will take on the function of raising or lowering. In order to prevent the lift car from crashing or sinking, stage equipment should be dismantled with over travel switches that can cut off power and cannot be automatically reset and installed in the machine room, it can achieve the lifting of a double-layer tabletop. Multiple lifting platforms can be formed as needed and different steps can be formed within the travel range to meet the needs of meetings and performances; Pavilion, Terrace, Tower, Pavilion; Ideal props.

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.


SacramentoElectric clothes drying elevatorPrices are rising



Construction electric elevators outside the lightning protection range

Energy costs.Protective measures should comply with regulatory requirements.

Normal operation starts. Click on this free download of construction technical information. Safety limit devices should be installed on electric elevators for construction, with upper and lower limit switches that are sensitive and reliable.

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

Sacramento.Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.