Proskov10 meter electric lifting platformCommon problems in the processing process

announcer:hp935HP175192871 release time:2024-01-23 18:43:19

It is understood that the scissor type lifting platform is a widely used specialized equipment for high-altitude operations. Its shear fork mechanical structure provides high stability for the lifting platform, wide working platform, and high load-bearing capacity, making the range of high-altitude operations larger and suitable for multiple people working simultaneously. The lifting power is divided into 24V, 220V or 380V power supplies, diesel engines, using Italian and domestic hydraulic pump stations, and the table top is equipped with anti slip insulation buckle plates, which have anti slip, insulation, and safety features. Please rest assured to use.

From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time,ProskovNiuli brand electric elevator, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machinery

Proskov.8m; When the lifting speed is greater than 0.8m/s, after the upper limit switch is triggered by the hanging cage, the upper small safety distance L should meet the following requirements: L=8+0.1V2, where L is the upper safety distance; V: Increase speed

Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors, or other lower suspended structures, the protective measures taken should comply with the specification requirements.

Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation,ProskovMobile small electric elevator, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Non automatic reset upper and lower limit switches should be installed at both the upper and lower ends of the stroke which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers),

The motor of the hydraulic guide rail lifting platform is set around the wellbore, occupying a relatively small area, improving the utilization rate of the wellbore area.

Analysis project.The bearing capacity of the ground under the concrete foundation plate should be greater than 0.15Mpa.

Before operating the construction electric elevator,ProskovElectric high-altitude elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.


Proskov10 meter electric lifting platformCommon problems in the processing process



Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

management.When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.

The impact load can cause early wear, fracture, and fragmentation of mechanical structural components, as well as generate impact pressure in the hydraulic system, which in turn can damage hydraulic components, oil seals, and high-pressure oil

High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

Proskov.Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, etc., and the production should meet the design requirements.