HejinChain guide rail lifting cargo elevatorWidely used in recent years

announcer:hp779HP136589660 release time:2024-05-26 20:06:27

The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory

Does the cleanliness of the hydraulic station have relevant rules and requirements?

Hejin.It is strictly prohibited to connect the motor of the lifting platform to the wrong power supply. It should be ensured that the voltage is 380v or 220v, and daily cleaning work should be carried out. Dust and debris on the motor should be cleaned in a timely manner.

Low cost: Compared to the scissor type mobile lifting platform, the cost is much lower. Therefore, it is necessary to consider the use range, frequency of work, load and other factors of the lifting platform to select a lifting platform suitable for the work requirements.

.In addition to having a fixed mode, there are also types of mobile elevators. As the name implies, it is a combination of lifting equipment and on-board systems. This type of lifting equipment is very flexible to move, and of course, it is better to use it. For example, there are such lifting equipment in airports, and stations or stadiums may also be equipped with such equipment, as it can be moved by itself, The scope of work is not limited to a certain place, but can be used wherever lifting operations are required. For example, when installing outdoor advertisements, some advertisements are relatively high in height. At this time, mobile lifting equipment can be used to send billboards or staff to a designated height for work. This type of equipment can also be divided into two types according to the driving mode: hydraulic lifting and electric lifting. The so-called hydraulic lifting is the use of hydraulic oil to drive to achieve a specified height. The electric mode is driven by a motor or tooth to lift to a certain height. However, currently, hydraulic lifting platforms are more widely used.

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes,Hejin5 ton lifting cargo elevator, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

Test the goods elevator every day to see if it can operate normally.


HejinChain guide rail lifting cargo elevatorWidely used in recent years



Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

Manual hydraulic lifting platform application Manual hydraulic platform performance: The manual hydraulic platform truck is made of high-strength steel,HejinProfessional cargo elevator, safety, and reliability. It is equipped with a safety valve a fully sealed oil cylinder,HejinGuide rail type lifting cargo elevator, making it easy to operate. Equipped with a guide wheel to save the operator's physical strength, and can protect the load wheel and pallet load wheel. Unique hydraulic pump design, the pump is simple and designed to maintain an ideal height for pipeline loading and unloading operations; The unique design concept makes the operator's operation simple and convenient.

Many people believe that the mechanical strength of the elevator itself is relatively high when using the elevator so the installation method specified in the manual is not strictly followed during the installation process. However, this can lead to increased wear of parts and inflexibility in operation. In addition, it is necessary to pay attention to the installation precautions corresponding to the working environment and not be careless. Correct installation, use, and maintenance of the elevator are important steps to ensure the normal operation of mechanical equipment. Therefore, when installing the elevator, please be sure to carefully assemble and use it in strict accordance with the following installation and use related matters.

How many?.Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.

Guide rail elevator (also known as cargo elevator) is a non scissor fork type hydraulic lifting platform, mainly used in industrial buildings, restaurants, warehouses, docks, workshops, and other places where vertical cargo handling is required between two or more floors. The low height is particularly suitable for sites that are not suitable for digging pits on site. What issues should we pay attention to in these places where elevators are used?

Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.


HejinChain guide rail lifting cargo elevatorWidely used in recent years



The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory

Installation works.Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines, adjusting the working height during workpiece assembly, feeding materials to loading machines at high altitudes, lifting components during assembly of large equipment, matching storage and loading sites with forklift trucks and other transportation vehicles for rapid loading and unloading of goods, vehicle lifting, fixed three-dimensional parking, and other places.

In our daily life today, hydraulic cargo elevators are also increasingly widely used and deeply loved by customers. As a lifting tool, the maintenance of cargo elevators should not be careless. The following editor will introduce the daily maintenance of hydraulic cargo elevators.

The common types of elevators will be briefly introduced here. I hope you can have a better understanding of this product. Currently, this product can be said to be sold well in China, because many places need to use this kind of product with lifting function and flexible movement. Now, companies specializing in producing this type of product combine with extensive external publicity on the Internet, Friends in need can directly find the corresponding company on the Internet, performance, and price information of these products. They can purchase directly through the Internet.

Hejin.Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

The brake operators of each mechanism on the equipment should regularly check and adjust the clearance of the brake shoe and brake wheel, ensuring flexibility and reliability. Long term improvement of the elevator factory, a 20 year old brand with competitive prices and guaranteed quality!

The brake operators of each mechanism on the equipment should regularly check and adjust the clearance of the brake shoe and brake wheel, ensuring flexibility and reliability. Long term improvement of the elevator factory, a 20 year old brand with competitive prices and guaranteed quality!