When a cargo elevator fails,LaredoFixed lifting cargo elevator, it should be repaired by professional personnel. It is not allowed to modify the cargo elevator without permission.

Goods should be stacked well on the platform, and should not be tilted. When the goods elevator is lifting or lowering beyond the scope of the platform, no one should stand around to watch.

Laredo.'The sinking of a cargo elevator is a phenomenon where the table surface drops due to gravity after a certain period of time after rising to a specified position. Of course, this problem must be abnormal, so how can we solve it?'? The first step is to find the reason, and the following editor summarizes the ultimate solution.

'Using the elevator is not about maintaining and overhauling the equipment after it has failed. It is important to maintain the equipment in accordance with the correct maintenance and overhaul. First, do the preparatory work to eliminate all possible fault problems and accidents. I hope that today's summary of knowledge points by the editor can help everyone.'.

.Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole and tighten with the hexagon socket. After that, remove the motor shaft key.

Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness,LaredoFixed lifting cargo elevator, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.

It should be noted that compared to some lifting platforms in certain venues, protective barriers are generally added to the platform. As lifting platforms belong to special equipment, the National Quality Inspection Bureau strictly inspects this area. Any lifting platforms that are deemed to have safety hazards must be removed. Therefore when personnel ask if you need to add guardrails, do not blindly refuse, and consider whether it is necessary based on the site of use. 'In addition, it is necessary to possess two types of certificates, namely, the Special Equipment Manufacturing License of the People's Republic of China and the Special Equipment Installation, Transformation, and Maintenance License of the People's Republic of China before production, installation, and maintenance can be conducted. Therefore, it is necessary to ask the manufacturer whether they possess these two types of certificates.'.


LaredoFixed guide rail type cargo elevatorThe environment promotes the help of enterprises



The cleanliness of the hydraulic station is an important aspect of the elevator hydraulic station, so it should not be taken lightly. Moreover, from a professional perspective, there are relevant rules and requirements. You should refer to the specification manual, so that you can have a correct understanding and know how to achieve better cleanliness.

Many times, when ordering a large lifting platform, the designer will first consider various factors before designing, including the size during transportation, to prevent it from being difficult to transport to the customer's installation site after being too wide. Therefore, during design and manufacturing, it is necessary to consider separate assembly or table split to meet the requirements. At the same time, it is also necessary to consider the bearing capacity of the split, design and manufacture on the premise of ensuring the load capacity and stability, lifted and moved.

Frequently check for water accumulation and humidity. It is inevitable for aerial vehicles to drive in rainy and snowy weather, or muddy roads. The bottom and some gaps and indoor floors are prone to sludge accumulation. If the owner does not clean them in a timely manner, this can cause moisture to hide. Therefore, doors, bottom corners of tree trunks, key holes, and wiper brackets, as well as other areas, should be regularly inspected, and the drainage holes in the doors and various parts should be kept unblocked to ensure that the car seat covers, carpets, prevent rust from forming parts.

Inspection environment.The hydraulic lifting platform can be divided into four wheeled mobile type, two wheeled traction type, vehicle modified type, vehicle type, auxiliary self-propelled type, and the lifting height varies from a meter to 1 meter.

To ensure excellent power supply at the installation site,LaredoBuilding guide rail lifting cargo elevator, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

When a cargo elevator fails, it should be repaired by professional personnel. It is not allowed to modify the cargo elevator without permission.


LaredoFixed guide rail type cargo elevatorThe environment promotes the help of enterprises



The hydraulic lifting platform can be divided into four wheeled mobile type, two wheeled traction type, vehicle modified type, vehicle type, auxiliary self-propelled type, and the lifting height varies from a meter to 1 meter.

Where is good.Walking: assisted self-propelled, two wheel traction, self driving, and car modification.

When using, the four legs should be firmly supported on a solid ground (subject to the fact that the walking wheel is about to leave the ground). Sleepers can be used when necessary.

To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Laredo.Unscrew the screws on the dustproof hole on the outer side of the elevator flange adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

What is the new price of fixed elevators? Fixed elevators are currently very popular in the market. Due to different manufacturers, different materials, different load ratings and different brand awareness, the prices also vary. Currently, the prices of fixed elevators produced in the domestic market are: rated load 1-5 tons, lifting height 7 meters, table size 2500 mm * 2000 mm, and the price is around 27000-45000 yuan; The rated load is 1-3 tons, the lifting height is 0 meters, the table size is 2300 mm * 2000 mm, and the price is around yuan. Rated load and lifting height of each fixed elevator,

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.