BaileAtha I6-ton cargo elevatorWhat are the industries

announcer:hp779HP136589660 release time:2024-05-07 16:41:19

Is the water cooling and air cooling of the hydraulic station the same?

The hydraulic lifting platform mainly uses hydraulic oil pressure transmission to achieve the lifting function. Its shear fork mechanical structure provides stability for the lift. The wide working platform and high bearing capacity make the high-altitude operation range wide and suitable for multiple people to work simultaneously. It makes aerial work efficient and guaranteed.

BaileAtha I.Any kind of machine or equipment will undergo a series of inspections and debugging before leaving the factory, the same is true. Of course, during the internship, there will still be some questions about the elevator, but if there is no contact, just mastering some specific information can effectively handle these questions.

It is strictly prohibited for personnel to climb up and down the floors by using the goods elevator privately.

.Many people believe that the mechanical strength of the elevator itself is relatively high when using the elevator, so the installation method specified in the manual is not strictly followed during the installation process. However, this can lead to increased wear of parts and inflexibility in operation. In addition, it is necessary to pay attention to the installation precautions corresponding to the working environment and not be careless. Correct installation, use, and maintenance of the elevator are important steps to ensure the normal operation of mechanical equipment. Therefore, when installing the elevator, please be sure to carefully assemble and use it in strict accordance with the following installation and use related matters.

Nowadays, small and medium-sized enterprises are products with the idea of good quality and preferential prices.

Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines, loading and unloading materials, adjusting the working height during workpiece assembly,BaileAtha IHydraulic guide rail type cargo elevator, feeding materials to loading machines at high altitudes, lifting components during assembly of large equipment, matching storage and loading sites with forklift trucks and other transportation vehicles for rapid loading and unloading of goods, vehicle lifting, fixed three-dimensional parking, and other places.


BaileAtha I6-ton cargo elevatorWhat are the industries



The hydraulic lifting platform can be divided into four wheeled mobile type, two wheeled traction type, vehicle modified type, vehicle type, auxiliary self-propelled type and the lifting height varies from a meter to 1 meter.

Main structure and purpose of guide rail type elevator: The mechanical part of guide rail type elevator mainly includes three parts: lifting device, track device, and belt changing device. The lifting device is mainly used to suspend the lifted person, which is the core part of the entire mechanism. The role of track device is mainly to provide movement trajectory, making operation more smooth. The belt changing device is used to switch tracks when the elevator is about to pass through the door. The internal structure of the lifting device is mainly composed of a gear mechanism a bracket, a worm gear,BaileAtha IThree ton lifting cargo elevator, a guide mechanism, a lifting arm, upper and lower shells, etc. Gear mechanism Gear mechanism mainly includes large and small gears, winding pulley, and safety device composed of stop buckle and torsion spring.

To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, two wheel traction, self driving, and car modification.

To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Outriggers: mechanical outriggers, hydraulic outriggers,BaileAtha I3 ton fixed lifting cargo elevator, ordinary hand cranking outriggers, and pull-out outriggers.


BaileAtha I6-ton cargo elevatorWhat are the industries



What is the new price for fixed elevators? Professional improvement of the quality assurance of the elevator factory. Preferential activities are ongoing, welcome new and old customers to consult

For more, please check.The common types of elevators will be briefly introduced here. I hope you can have a better understanding of this product. Currently, this product can be said to be sold well in China, because many places need to use this kind of product with lifting function and flexible movement. Now, Friends in need can directly find the corresponding company on the Internet, and then have a brief understanding of the model, performance, and price information of these products. They can purchase directly through the Internet.

Chemical derusting is a type of derusting that uses acid to chemically react with the metal parts of the screw elevator to remove the rust products on the rust surface of the push rod. This type of derusting is mainly used for large mechanical screw elevators, and attention should be paid to protecting precision components such as electronic instruments during use to avoid acid corrosion.

Precautions for using guide rail type elevators: Overloading and transporting flammable and explosive products are strictly prohibited.

BaileAtha I.Before connecting the motor to the elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress, first screw on the mounting bolts at any diagonal position, but do not tighten them. Then screw on the other two mounting bolts at diagonal positions, and then tighten the four mounting bolts one by one. After that, tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data, and the use of elevators and lifting platforms shall be checked

Incorrect connection of the elevator motor When a coil, coil group, or one phase winding group is connected inversely, it can cause a serious imbalance in the three-phase current and cause the winding to overheat.

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters and the load capacity is about 10 tons.