LudasirenskaWarehouse elevatorProduct survey

announcer:hp779HP136589660 release time:2024-02-23 10:03:19

Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

The brake operators of each mechanism on the equipment should regularly check and adjust the clearance of the brake shoe and brake wheel, ensuring flexibility and reliability. Long term improvement of the elevator factory, a 20 year old brand with competitive prices and guaranteed quality!

Ludasirenska.All previous inspections and commissioning have been carried out, and all technical indicators have met the design requirements. When using, it is only necessary to connect the power supply, and there is no need to adjust the hydraulic and electrical systems.

Goods should be stacked well on the platform, and should not be tilted. When the goods elevator is lifting or lowering beyond the scope of the platform, no one should stand around to watch.

.The anti rust work of aerial vehicles is generally something that needs attention when they have not been used for a long time. How should we protect the body of aerial vehicles from corrosion? This is actually a simple matter of not having to spend money on anti-corrosion at the repair station. As long as we car owners use some materials they can find on their own, we can achieve this. At the same time, paying attention to driving habits can ensure that high-altitude work vehicles do not rust. Here are a few points for reference.

The load of this series of products is divided into 0.1 to 0.8 tons, and can also be customized according to user requirements, with a load of up to 10 tons.

Knowledge popularization and superior performance of scissor fork type fixed lifting platform: equipped with safety devices to prevent overloading of the lifting platform; Equipped with a protection valve to prevent hydraulic oil pipe from cracking; Equipped with an emergency lowering device for sudden power failure; The doors of the upper and lower floors are equipped with safety devices that interlock with the system.


LudasirenskaWarehouse elevatorProduct survey



To ensure excellent power supply at the installation site, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Replace with new oil and do not intermittently use the old oil, otherwise the moving parts in the system will accelerate wear.

Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type, mesh type, and iron plate sealed type.

Welcome calls .Incorrect connection of the elevator motor When a coil coil group, or one phase winding group is connected inversely, directly operated by the manufacturer. Because fixed elevators are mechanical equipment, the quality and performance of the product are good. Do not accept products from some manufacturers that do not meet the quality standards, in order to avoid some safety hazards in use.

Precautions for using guide rail type elevators: Overloading and transporting flammable and explosive products are strictly prohibited.


LudasirenskaWarehouse elevatorProduct survey



What is the new price of fixed elevators? Fixed elevators are currently very popular in the market. Due to different manufacturers, different materials, different load ratings, the prices also vary. Currently, the prices of fixed elevators produced in the domestic market are: rated load 1-5 tons, lifting height 7 meters, table size 2500 mm * 2000 mm, and the price is around 27000-45000 yuan; The rated load is 1-3 tons,LudasirenskaBody guide rail type cargo elevator, the lifting height is 0 meters, the table size is 2300 mm * 2000 mm, and the price is around yuan. Rated load and lifting height of each fixed elevator,

safety requirements .Regardless of whether it is used outdoors or indoors, it is inevitable that some small problems will occur after a long period of time. At this time, what we should do is to maintain and maintain the elevator. How to follow the steps correctly becomes a difficult problem. Let me explain it to you.

The main structure and use of the guide rail type elevator are closed gear transmission, and the large and small gears are made of steel. After quenching and tempering treatment, they belong to the soft tooth surface. As the common failure form of closed soft tooth surface gear transmission is tooth surface pitting the design is based on the tooth surface fatigue strength and checked based on the tooth root bending fatigue strength. The bracket bracket is used to fix and support all mechanical parts and some electrical components of the elevator chassis. It is mainly welded from parts such as side plates, connecting tubes, and connecting pieces. The materials are all selected, including the thickness of both sides of the plate, products, and tens of millions of products. Professional elevator factory transactions are safe and guaranteed. At the same time, in order to reduce the weight of the bracket, many process holes are designed on both sides of the plate. The worm gear and worm mechanism has the advantages of large transmission ratio, compact structure, small impact load, stable transmission, low noise, and has the characteristics of reverse self-locking. It can ensure that the transmission mechanism can self-lock when the motor is powered off during patient handling, so a worm gear reducer is selected. The involute worm is used and the material is steel. Its spiral surface is quenched to improve transmission efficiency and increase wear resistance. The worm gear is made of polyformaldehyde. Plastic worm wheels have the advantages of good processing economy, stable transmission, vibration absorption and noise reduction, light weight, wear resistance, making the design of the elevator more humanized.

Is the water cooling and air cooling of the hydraulic station the same?

Ludasirenska.Large logistics warehousing equipment service company with guaranteed prices and guaranteed services directly operated by the manufacturer. Because fixed elevators are mechanical equipment, in order to avoid some safety hazards in use.

Characteristics of hydraulic elevators: Hydraulic lifting platform products are divided into curved arm type hydraulic lifting machines, scissors type hydraulic lifting machines, mast type hydraulic lifts, and straight arm type hydraulic lifts according to their working modes. Hydraulic elevator is a replacement product of folding arm elevator (lifting platform) and scissor fork elevator (lifting platform). It can be widely used for the decoration and decoration of stations, docks, airports, hotels, posts and telecommunications,LudasirenskaFixed hydraulic lifting cargo elevator, municipal gardens, garages, cleaning companies, public building facades, or the installation and maintenance of power systems, etc. This elevator has the advantages of light weight, self-propelled walking, electric starting, self supporting legs, simple operation, large working area, and especially the ability to cross obstacles for aerial work.

Before connecting the motor to the elevator,LudasirenskaRail lift cargo elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress, first screw on the mounting bolts at any diagonal position, and then tighten the four mounting bolts one by one. After that, tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data and the use of elevators and lifting platforms shall be checked