Sesto San GiovanniFixed guide rail lifting cargo elevatorAnalysis of problems with application effects

announcer:hp779HP136589660 release time:2024-02-20 11:12:27

Connect the motor to the elevator naturally. During connection, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

The motor winding is short-circuited. When a short circuit fault occurs in the motor winding, the short circuit current is much larger than the normal working current, which increases the copper loss of the winding,Sesto San GiovanniWhere is there a lift for goods, causing the winding to overheat or even burn out.

Sesto San Giovanni.Main structure and purpose of guide rail type elevator: The mechanical part of guide rail type elevator mainly includes three parts: lifting device, track device, and belt changing device. The lifting device is mainly used to suspend the lifted person, which is the core part of the entire mechanism. The role of track device is mainly to provide movement trajectory, making operation more smooth. The belt changing device is used to switch tracks when the elevator is about to pass through the door. The internal structure of the lifting device is mainly composed of a gear mechanism, a bracket, a worm gear, a guide mechanism, a lifting arm, upper and lower shells, etc. Gear mechanism Gear mechanism mainly includes large and small gears, winding pulley, the platform is level with the ground and safety device composed of stop buckle and torsion spring.

Scissor type fixed lifting platform is a transportation and loading equipment that transports goods from one height to another. After operation, without occupying ground space and affecting passage passage.

.The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory

Precautions for elevator installation: Keep the access road of external construction elevators smooth and have sufficient space for parking equipment. When using a steam crane for auxiliary installation, full consideration should be given to whether the on-site environment meets the operating conditions of the steam crane.

The load of this series of products is divided into 0.1 to 0.8 tons, and can also be customized according to user requirements, with a load of up to 10 tons.


Sesto San GiovanniFixed guide rail lifting cargo elevatorAnalysis of problems with application effects



Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

Although the cargo elevator has good safety, in actual work, if you do not pay attention to detailed maintenance there may be accidents, so we should pay attention to it when performing daily maintenance.

Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, and promptly remove all faults; When installing, disassembling, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.

Information recommendation.Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

Outriggers: mechanical outriggers, hydraulic outriggers, ordinary hand cranking outriggers, and pull-out outriggers.

Large logistics warehousing equipment service company with guaranteed prices and guaranteed services, directly operated by the manufacturer. Because fixed elevators are mechanical equipment, the quality and performance of the product are good. Do not accept products from some manufacturers that do not meet the quality standards, in order to avoid some safety hazards in use.


Sesto San GiovanniFixed guide rail lifting cargo elevatorAnalysis of problems with application effects



Before installing the elevator, confirm whether the motor and the elevator are intact, and strictly check whether the dimensions of each part connecting the motor and the elevator match. Here are the dimensions and fit tolerances of the positioning boss, input shaft, and elevator groove of the motor.

average method.Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type mesh type, and iron plate sealed type.

Small pneumatic or electric derusting, which uses the principle of friction generated by air compression or electromagnetic effects to polish and remove rust on the surface of a spiral elevator, can be used for precision instrument push rods or for enterprises that require micro operation of spiral elevators.

Fixed elevator is a transportation equipment that directly lifts and loads goods from the ground. It is mainly used for goods transportation between height differences in production lines material loading and unloading, and other places. So what is the new price for fixed elevators?

Sesto San Giovanni.Frequently check for water accumulation and humidity. It is inevitable for aerial vehicles to drive in rainy and snowy weather fixed three-dimensional parking, or muddy roads. The bottom and some gaps and indoor floors are prone to sludge accumulation. If the owner does not clean them in a timely manner,Sesto San GiovanniOutdoor guide rail type cargo elevator, this can cause moisture to hide. Therefore, activities in the outer edges of wheel hubs, doors, bottom corners of tree trunks, key holes, and wiper brackets, should be regularly inspected, and the drainage holes in the doors and various parts should be kept unblocked to ensure that the car seat covers, such as humidity, carpets, and floors, prevent rust from forming parts.

Carefully prepare a special construction plan for installation and construction, and provide safety technical disclosure to installation personnel.

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases, the windings will be burned.