Horqin Manual hydraulic lifting platformAnswers to frequently asked questions

announcer:hp695HP135175170 release time:2024-02-07 09:57:26

In the construction elevator, the switch box also has leakage protection equipment, and its wires and cables have good insulation without leakage. The metal passing through the wires is not rusted, and its damage is close to zero. His steel wire rope should comply with the corresponding configuration requirements, without any issues of strand breakage or shrinkage, and of course, the number of broken wires should not exceed the corresponding standards. His pulley movement is very flexible.

The hook of the seat belt should not be hung on unstable or moving objects. High priced and various specifications of scissor lift manufacturers provide timely supply, with high cost-effectiveness, and have become the preferred brand for many wire products. Welcome to purchase!

Horqin .The axle manufacturer's oil cylinder is leaking and the oil cylinder seal is being replaced. The lifting platform does not lower and the lowering valve is malfunctioning. When the lowering button is pressed, check if the lowering valve is energized. If there is no electricity, try to eliminate it; If there is electricity, troubleshoot the lowering valve itself or replace the lowering valve. The lowering valve should be kept clean.

Operating cost advantage: Low failure rate. Due to the use of advanced hydraulic systems and good methods,Horqin Hydraulic lifting platform and hydraulic lifting platform,Horqin Fixed electric hydraulic lifting platform, the failure rate of elevator operation can be minimized. Low power consumption: When the hydraulic elevator descends, it is driven by the pressure generated by its own weight, which greatly saves energy.

.Operating cost advantage: Low failure rate. Due to the use of advanced hydraulic systems and good methods, the failure rate of elevator operation can be minimized. Low power consumption: When the hydraulic elevator descends, it is driven by the pressure generated by its own weight, which greatly saves energy.

Guide rail type cargo elevators are a type of equipment for transporting heavy objects up and down, and have great applications in factories, workshops, and other places. For this type of heavy machinery, its daily maintenance and upkeep are very important, because some small details can have a significant impact on the operation safety of the equipment if not paid attention to. Therefore, attention should be paid to the daily maintenance of cargo elevators.

Check the rollers, intermediate shafts, efficiency, and usable area of electric elevators, most high-rise buildings will divide electric elevators into arrays, with each group responsible for a portion of the floors, and make different adjustments and scheduling based on the usage mode of different floors at different times.

The question of how to extend the service life of hydraulic lifting platforms will be briefly discussed here. Many people may not be familiar with this type of equipment, especially those who do not know which factories are producing such equipment. It is recommended that friends can search online because many sellers and producers of this type of equipment now have their own official websites, and there are more online

How to maintain elevators in winter is one reason and the primary reason. Many workers in other industries do not know that hydraulic elevators use different types of hydraulic oil in summer and winter. Often, at low temperatures, the hydraulic oil used in summer can become, or even freeze. After entering low temperatures in winter, it is important to remember to replace hydraulic oil containing antifreeze, which is suitable for working at low temperatures.

Interpretation and observation.The correct construction inspection of the airport is to first inspect the foundation to see if there is any water accumulation and to see if the grounding system meets the requirements. We also need to see how the structural bolts of this frame are tightened, it can be divided into two types: open type and closed type. Of course, there are also many safety equipment for elevators.

The surface of each part of the brush should be kept clean, and the brush pressure should be adjusted to ensure that its area is not less than 50%. Specializing in product and renewable resource business, including: scissor lift manufacturers

Check the hydraulic oil quality and level. When the lifting platform is raised to a high position, the hydraulic oil level should be 40-50 millimeters higher than the bottom of the oil tank. When the color of the hydraulic oil darkens, the oil becomes sticky, or there are foreign objects such as gravel in the oil, tighten the pipe joint.


Horqin Manual hydraulic lifting platformAnswers to frequently asked questions



The product has a sturdy structure it should be replaced immediately; When there is looseness in the connection part,Horqin Electric hydraulic lifting platform, a large load-bearing capacity, smooth lifting, simple and convenient installation and maintenance, making it an ideal and economical cargo conveying equipment for replacing elevators between low floors. The editor will tell you about the level

Where can I find it?.The second is that the steel will have obvious thermal expansion effect at low temperature. Although this property of steel will be taken into account when designing and manufacturing hydraulic elevators, the environment is different after all. Under low conditions, the steel will have some unstable performance, such as hardness increase, toughness decline, etc. At this time, more attention should be paid to the maintenance of equipment to keep key parts to avoid dry grinding.

Secondly, there should be no dirt on the friction surface. If there is any dirt, it needs to be washed off with gasoline or thinner; The reduction gearbox, gearbox external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; The correct maintenance method for hydraulic guide rail elevators is to regularly check the steel wire ropes in various parts for any breakage or looseness. If this phenomenon is found, it should be tightened in a timely manner. The tightness of the connecting bolts of the equipment should be checked when the body is under pressure. All connecting shafts should be equipped with split pins; According to regulations, check the normal operation of each mechanism whether there is noise or malfunction, and promptly eliminate all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to ensure that the centerline of the reducer and gear is parallel, and the meshing clearance is appropriate; Regularly conduct a comprehensive inspection of the equipment to check if there is any damage to the wires and cables, and if there is any overheating of the motor. Replace and eliminate the fault in a timely manner before continuing operation; Ensure the bearings of the motor, each box, distribution box, and electrical

Remove and disassemble the lowering valve, blow the valve core clean with compressed air, and then reinstall it.

Horqin .The seat belt needs to be inspected every six months, with a load of 225 kilograms. The test time is five minutes. After the test, and the joints must not be loose. All joints must be tightened.

During use and keep records of the experiment. Any unqualified seat belts should be immediately stopped from use.

Precautions for daily maintenance of hydraulic elevator: Check all hydraulic pipelines and joints of the hydraulic elevator. The pipelines must not be damaged, the elevator should be placed on a solid and flat ground to prevent tipping during operation. Press&quo; Rising; Or&quo; Descending; Press the button to frequently check and maintain the various components of the elevator when lifting the workbench. If the workbench does not move, it should be immediately stopped for inspection. When the working pressure of the electric elevator is found to be too high or the sound is abnormal it should be immediately shut down for inspection to avoid serious mechanical damage; Regularly check the working status of the shaft pin every month. If any loose shaft pin or screw is found, it must be locked tightly to prevent accidents caused by the shaft pin falling off.