Xinle20 meter hydraulic liftWhat

announcer:hp695HP135175170 release time:2024-01-29 18:56:57

the hydraulic oil level should be 40-50 millimeters higher than the bottom of the oil tank. When the color of the hydraulic oil darkens, or there are foreign objects such as gravel in the oil, the hydraulic oil should be replaced in a timely manner. The hydraulic system of the lifting platform should be checked for hydraulic and pipeline connections. If the pipeline is damaged, it should be replaced immediately; When there is looseness in the connection part, tighten the pipe joint.

According to Beijing regulations, the arrival time is within 30 minutes.

Xinle.How should we extend the service life of hydraulic lifting platforms? In order to prolong the service life of such machinery and equipment, it is necessary to regularly inspect and maintain the equipment during use. For example, if there are various switch devices inside the machinery and equipment, it is necessary to regularly check whether these switches can be used normally and whether the switch points are in good condition during use. There will be an electrical box and distribution box inside the elevator, and these devices are prone to dust accumulation outside. If the dust accumulates too much it may cause rust on the outside of the electrical box. Therefore, when using them, it is necessary to regularly remove the dust on the outside of various boxes. Generally, this job is what operators should do after each operation.

High altitude work requires the use of tool bags, and heavier and larger high-altitude work tools should be hung on stable components and cannot be placed randomly to avoid the occurrence of high-altitude falling accidents.

.When working in a hot environment pay attention to heat dissipation.

Preparation before folding and installation of the elevator. Carefully prepare a special construction plan for installation and provide safety technical disclosure to the installation personnel.

The inconsistent rotation axis of the support rod in the middle of the hydraulic lifting platform results in the lifting platform being unable to function properly, causing serious damage to the platform and causing the table to tilt. Please carefully check that the general shear type high-altitude work platform was not strictly tested for tilt before leaving the factory, and was put into the market, causing many accidents. For small enterprises, they are not very concerned about this aspect of tilt detection, This is also why there are such a large number of lifting equipment with this problem. The problems with the oil cylinder and power unit system are often due to insufficient power and substandard oil cylinder quality, which are also very important issues for enterprises themselves.


Xinle20 meter hydraulic liftWhat



During use, the elevator should be placed on a solid and flat ground to prevent tipping during operation. Press&quo; Rising; Or&quo; Descending; Press the button to frequently check and maintain the various components of the elevator when lifting the workbench. If the workbench does not move, it should be immediately stopped for inspection. When the working pressure of the electric elevator is found to be too high or the sound is abnormal, it should be immediately shut down for inspection to avoid serious mechanical damage; Regularly check the working status of the shaft pin every month. If any loose shaft pin or screw is found, it must be locked tightly to prevent accidents caused by the shaft pin falling off.

Secondly, there should be no dirt on the friction surface. If there is any dirt, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; The correct maintenance method for hydraulic guide rail elevators is to regularly check the steel wire ropes in various parts for any breakage or looseness. If this phenomenon is found, it should be replaced in a timely manner. The maintenance of the steel wire ropes must be strictly carried out in accordance with the specifications; Check the connection status of each part according to the braking regulations. If there is any looseness, it should be tightened in a timely manner. The tightness of the connecting bolts of the equipment should be checked when the body is under pressure. All connecting shafts should be equipped with split pins; According to regulations, check the normal operation of each mechanism, whether there is noise or malfunction, and promptly eliminate all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to ensure that the centerline of the reducer and gear is parallel, and the meshing clearance is appropriate; Regularly conduct a comprehensive inspection of the equipment to check if there is any damage to the wires and cables and if there is any overheating of the motor. Replace and eliminate the fault in a timely manner before continuing operation; Ensure the bearings of the motor, each box, distribution box, and electrical

Outdoor elevators and factory cargo elevators are heavy lifting mechanical equipment. Outdoor elevators are used for transporting goods between floors of buildings, and are specialized hydraulic cargo elevator products. They are mainly used for transporting goods up and down between various working floors; Vertical garage and car lift between garage floors. The hydraulic system of the product is equipped with anti fall and overload protection devices, and operation buttons can be set on each floor and lifting platform workbench to achieve multi-point operation.

Recommendation and consultation.Good stability: The overflow valve can prevent excessive system pressure during upward movement. Emergency manual valve: In case of power failure, it can cause the elevator car to descend to the nearest floor position and open the door. Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position; Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops.

Use a heavy crane to lift the cage and lift it from above the standard section

Remove and disassemble the hydraulic lift cargo elevator lowering valve, blow out the plunger with compressed air, then install it and reinstall it.


Xinle20 meter hydraulic liftWhat



Regularly check whether the operation of each mechanism is normal and whether there is any noise. If any faults are found, they must be promptly eliminated. For a long time, the manufacturer of scissors lift has never changed hands to avoid price difference,XinleGuide rail elevator, and the price is 20% higher than the market value! More than one ton is more expensive!

Discount.When using the distribution box, the electric leakage switch meets the requirements for construction elevators. If the fixed elevator installed is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Any machinery needs to be maintained after use, let alone large machinery. Poor maintenance of elevators after use can reduce the lifespan of elevators. Today, the editor will tell you how to maintain elevators after use. In order to maintain the good technical condition of elevator machinery, ensure the safe use of on-site construction machinery, extend the service life of equipment, construction enterprises must maintain according to the relevant regulations According to maintenance regulations, and it is strictly prohibited for equipment to be taken out of warranty or repair.

Loosening: The motor fan makes a sound when it rotates. If the screws that fix the motor are loose, coupled with its own vibration, the motor collides with other components, resulting in a sound; The joints of each pin shaft are dry, lacking oil, and there is hard friction between the iron parts,XinleHydraulic lifting platform manufacturer, which not only damages the components but also produces abnormal noises. Therefore, the editor should emphasize again that timely maintenance and frequent refueling are important; If the hydraulic lifting platform does not rise, there is air in the hydraulic oil. You can open the exhaust hole, add gas, and then tighten it again; Hydraulic oil solidification: replace the hydraulic oil; Oil leakage: Check if there is any oil leakage at the interfaces of each oil pipe. If there is any oil leakage, replace it in a timely manner; Motor reversal: Check for wiring errors; (Manufacturers of hydraulic lifting platforms who do not understand electricity in a timely manner)

Xinle.When installing, disassembling, and adjusting the rotating mechanism,XinleScissor type hydraulic lifting platform, it is important to ensure that the centerline of the reducer of the rotating mechanism is parallel to the centerline of the gear, and its meshing surface is not less than 70%. The meshing clearance should be suitable.

The daily maintenance of guide rail type cargo elevators should ensure that the transmission position where the grease nipple is located needs to be lubricated twice a month. For areas where grease cannot be added, it is necessary to clear the oil circuit or replace the grease nipple until butter can be added. Otherwise it is prohibited to use the equipment.

Regularly check all wires and cables for damage. Timely bandage and replace damaged parts. Various scissor lift manufacturers have formal qualifications. Welcome to inquire by phone and sincerely invite cooperation!