UlmElectric elevator 10 metersHow to correctly judge the factors

announcer:hp935HP175192871 release time:2024-01-14 13:01:01

The L distance depends on the selected wall mount model.

Installation verticality deviation guide rail frame erection height, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

Ulm.Folding arm electric elevators are mostly driven by hydraulic means, and the source of power for the hydraulic system is hydraulic oil. Only when the hydraulic oil quantity is sufficient and the oil quality is high, can the folding arm electric elevator provide greater torque output, how can we determine whether the newly added hydraulic oil quantity is sufficient? What is the hydraulic oil quantity standard?

As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.

.When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Work is essential, and the main protective accessories include safety belts, guardrails, protective covers, platforms and stairs, etc.


UlmElectric elevator 10 metersHow to correctly judge the factors



When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

Safety devices: Electric elevators for construction should be equipped with overload detection devices. When the load inside the cage exceeds 10% of the rated load capacity, the overload detection device will give a warning signal inside the cage,

When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

Focus on Development.The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology, smooth lifting and low noise.

The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

The verticality of the guide rail frame should meet the requirements of the specifications.


UlmElectric elevator 10 metersHow to correctly judge the factors



Monthly maintenance and inspection of hydraulic lifting platform rollers intermediate shafts and bearings,UlmElectric mobile hydraulic elevator,UlmElectric elevator lifting platform, oil cylinder pin shafts and bearings, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, blow out the plunger with compressed air,UlmElectric pulley elevator, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

demand.Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight greatly saving energy and reducing consumption.

The device should be used within the valid calibration period and operate effectively and reliably. The anti fall safety device should have a valid inspection certificate (or inspection report), and the validity period should not exceed 1 year. Anti fall safety devices have been manufactured for five years

Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops

Ulm.The quality of the standard section should comply with the product manual and specification requirements.

Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors, or other lower suspended structures, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.