EmerodAll electric small elevatorMarket supply and demand are in a weak balance

announcer:hp935HP175192871 release time:2024-01-10 12:53:21

When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test,Emerod10 meter self-propelled elevator, it worked normally.

Electric elevators used in various places.

Emerod.Setting requirements: Buffers should be installed below the suspension cage and counterweight running channel.

Monthly maintenance and inspection of hydraulic lifting platform rollers, intermediate shafts and bearings, oil cylinder pin shafts and bearings, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, blow out the plunger with compressed air, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

.In addition to ground protective fences,EmerodElectric six meter elevator, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings, a half height middle crossbar, and a toe board at least 150mm above the ground.

From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting, low noise, long service life,EmerodPlatform electric elevator, large load bearing capacity, and are relatively simple, making them suitable for use in stage equipment.

The entrance of each landing platform must be equipped with a landing door which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.


EmerodAll electric small elevatorMarket supply and demand are in a weak balance



Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

Equal effect.

Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

index.The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.

The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

Protective measures should comply with regulatory requirements.


EmerodAll electric small elevatorMarket supply and demand are in a weak balance



To meet the needs of choreographers and choreographers in different plays different heights of the lifting platform can be used to change the shape of the stage according to the requirements of the choreographers and choreographers, in order to adapt to the requirements of the plot for the scenery or venue, and save manpower and material resources for setting up. By using the tilting device of the lifting platform to form a tilted platform, a better highlighting effect can be achieved in various performances. According to the needs of the plot, special atmosphere and effects can be created. Even simple stage machinery often participates in performance activities, creating unexpected atmosphere and effects according to the needs of the plot. For example, using the low-speed descent of the lifting platform to represent a sunken ship in the sea, using the valves on the lifting platform and the sudden disappearance and appearance of actors on the lifting platform.

Installation materials.Use floor doors and cage door devices on construction sites where conditions permit.

Installation position of upper limit switch: Under normal working conditions, the distance between the upper limit switch and the upper limit switch is 0.15m for SC type construction electric elevators, and 0.15m for SS type construction electric elevators (person)

Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

Emerod.Stage equipment safety door. To prevent personnel from extending their heads, hands, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops

Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, and