AuorburgElectric elevator factoryRapid growth in market size

announcer:hp935HP175192871 release time:2023-12-22 10:29:11

The wall bracket of the construction electric elevator should be intact and reliably fixed, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

According to the needs of different performance genres, the form of the stage can be changed. For example, using an orchestra pit lift can combine a framed stage with a large lip or even an extended stage. In an experimental theater, using a lift can make the theater have various forms such as an end stage, an extended stage, an island stage an intermediate stage, a T-shaped stage, or a hall.

Auorburg.Is there a relevant rule requirement for the cleanliness of hydraulic stations?

Braking. The brake limit switch for partial motion control of the electric hoist traction machine. Assembly that restricts the operation of the lift car when it is opened to a high or low position; If the limit switch controls the overtravel switch. When the car travels to a high or low position,AuorburgElectric elevator 5 meters, it will take on the function of raising or lowering. In order to prevent the lift car from crashing or sinking, stage equipment should be dismantled with over travel switches that can cut off power and cannot be automatically reset, and installed in the machine room, rather than in the shaft; A buffer should be installed that can absorb the energy of the moving mechanism and reduce impact.

.The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements otherwise protective measures shall be taken.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, and corrosion of steel wire ropes


AuorburgElectric elevator factoryRapid growth in market size



Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

In addition, when adding hydraulic oil, it is necessary to ensure the quality of the hydraulic oil, as some hydraulic oil manufacturers will choose hydraulic oil with poor quality. Hydraulic oil such as hydraulic lifting platforms not only cannot have any effect on folding arm elevators, but also affects the working efficiency of folding arm electric elevators due to deterioration issues.

Spiral electric lifting mechanism: With all the functions of a regular lifting platform, the main feature is that the equipment occupies a small foundation pit and has a large stroke. The equipment has a height of only 200-500mm and a travel distance of up to 14m. It is particularly suitable for buildings with stages built on two or more floors due to space constraints.

Welcome calls .Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.


AuorburgElectric elevator factoryRapid growth in market size



Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods,AuorburgWarehouse electric elevator, the operating failure rate can be reduced to a low level.

index.During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

Lower limit switch: In normal working state,AuorburgMicro electric elevator, before the suspension cage touches the buffer the lower limit switch first acts.

Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean, and after changing the hydraulic oil, maintain sufficient space, and ensure that the lifting platform can be lifted to the rated lifting height.

Auorburg.Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods, the operating failure rate can be reduced to a low level.

Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends, it can automatically cut off the oil circuit and stop descent