Balbrigan12 meter electric elevatorApplication note

announcer:hp935HP175192871 release time:2023-12-21 12:35:20

Electric elevators used in various places.

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts,BalbriganElectric passenger lift, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

Balbrigan.The use of fully autonomous electric elevators can create more benefits and ensure safety in all aspects.

Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

.Installation and dismantling personnel and drivers should hold certificates to work.

When the landing door is closed, the full width of the lifting passage opening should be covered.

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.


Balbrigan12 meter electric elevatorApplication note



Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

Normal operation starts. Click on this free download of construction technical information. Safety limit devices should be installed on electric elevators for construction with upper and lower limit switches that are sensitive and reliable.

Principle of electric elevator rotary valve: When the electric elevator rises, the rotary valve will automatically open. To close the plug valve, it is necessary to first turn the handle to turn the plug to a 90 degree position until it is closed, and then turn the transmission handwheel to lower the plug and achieve sealing.

Latest consultation.The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements and record the inspection results.


Balbrigan12 meter electric elevatorApplication note



News Abstract: The development of the lifting platform industry will continue to grow in recent years! With the continuous development of electric lifting machinery for high-altitude operations in recent years, the products of electric lifting platform vehicles have been continuously improved, and various new technologies and materials have emerged,BalbriganElectric one ton elevator, making the further development of lifting platform vehicles possible.

Welcome calls .Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, when there is a major malfunction of the lifting platform, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, personnel and property losses.

Balbrigan.The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Horizontal lead screw mechanical electricity