WeltTricycle electric elevatorInterpretation and observation

announcer:hp935HP175192871 release time:2024-07-12 11:10:22

The motor of the hydraulic guide rail lifting platform is set around the wellbore occupying a relatively small area, improving the utilization rate of the wellbore area.

When the wall bracket cannot meet the requirements of the construction site, the bracket should be supported to prevent the electric elevator from overturning. Electrical and hydraulic systems should be maintained by professional personnel; When the battery level display is less than 40%

Later,WeltBackground axis electric elevator, when there is a major malfunction of the lifting platform, it should not be used again to avoid accidents, personnel and property losses.

.The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit,WeltElectric curved arm elevator, and verified by experts.

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

Work is essential, and the main protective accessories include safety belts guardrails, protective covers, platforms and stairs, etc.


WeltTricycle electric elevatorInterpretation and observation



Operating cost advantage and low failure rate: Due to the use of advanced hydraulic systems and good methods, the operating failure rate can be reduced to a low level.

The cleanliness of the hydraulic station is an important aspect of the electric elevator hydraulic station, so it should not be taken lightly. And from a professional perspective, there are relevant rules and requirements that should be referred to in the specification manual,WeltElevator electric platform, so as to have a correct understanding and know how to achieve good cleanliness.

Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

Quality recommendation.Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.


WeltTricycle electric elevatorInterpretation and observation



Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

Quality improvement.The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.

Before installing the construction electric elevator, the foundation should be inspected and approved before installation.

Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

Welt.Setting requirements: The wall bracket should use the manufacturer's matching standard products.

The motor of the hydraulic guide rail lifting platform is set around the wellbore occupying a relatively small area, improving the utilization rate of the wellbore area.

The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure