JinghaiElectric spiral rod elevatorWiring construction process

announcer:hp935HP175192871 release time:2024-06-16 19:30:53

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

Jinghai.It is strictly prohibited to use travel limit switches as switches to stop operation.

Setting requirements: The wall bracket should use the manufacturer's matching standard products.

.When the wall bracket adopts non matching standard products, and the valve can be opened and closed at any time; The installation of a rotary valve reduces the friction of the sealing components; Compact structure,JinghaiElectric banner elevator, small size, and space saving; Increased the service life of electric elevator pipelines and solved the problem of easy oil leakage.

When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.


JinghaiElectric spiral rod elevatorWiring construction process



The scaffolding of the parking platform should be laid tightly and firmly.

In addition to fixed modes, there are also types of car mounted mobile devices. As the name suggests, this type of lifting device is a combination of lifting equipment and car mounted systems. It is very flexible to move and of course, it is better to use it. For example, there are such lifting devices in airports, and car stations or sports stadiums may also be equipped with such devices, as they can be moved, So the scope of the operation is not limited to a specific place, but can be used wherever lifting operations are required. For example, when installing outdoor advertisements, some advertisements are relatively high in height. At this time, currently, hydraulic lifting platforms are more widely used.

Horizontal lead screw mechanical electricity

Design brand.Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.

Safety grounding device. In order to protect against electrical equipment. The metal casing of electrical equipment and the metal structure of electric elevators should be equipped with a safety grounding device. The grounding wire should operate multiple wires,JinghaiElectric tatami elevator,JinghaiFour meter electric elevator, and the neutral wire should not be arbitrarily held as a safety grounding wire. Its grounding resistance should not exceed 4 ohms; The power supply of the electric elevator can be cut off.


JinghaiElectric spiral rod elevatorWiring construction process



Remind customers that there are still many areas to pay attention to when maintaining and maintaining the lifting platform. We also hope that customers and friends can pay more attention when using it to ensure the safety of personnel and property, regularly maintain and extend its service life, and create greater benefits for the enterprise. What is the matching degree of electric elevators? Everyone has always been confused. In short the matching degree of electric elevators is how the height of the electric elevator can be combined with the operating height. Electric elevators are not used frequently, so we must make it clear based on the actual operating height and actual load capacity when using electric elevators. If the frequency is too high, We suggest considering purchasing a guide rail electric elevator or a scissor fork electric elevator. The scissor fork electric elevator can achieve a maximum load capacity of 100 tons, we recommend using a guide rail electric elevator. This type of electric elevator is not easy to malfunction under high-frequency operation, By solving the load capacity and frequency of use, the matching problem of electric elevators is effectively solved. Concept of electric elevator rotary valve: The electric elevator rotary valve is a type of valve that quickly opens and closes, and the rotary valve can reduce oil pipeline channels and optimize line settings.

Executive standard.It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easier

It is strictly prohibited to use travel limit switches as switches to stop operation.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

Jinghai.The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

When the landing door is closed, the full width of the lifting passage opening should be covered.