LudasirenskaSmall electric pulley elevatorHow to test insulation

announcer:hp935HP175192871 release time:2024-05-05 14:44:32

The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances, when the net height of the building entrance is less than 0m, it is allowed to lower the height of the lower door opening but in any case, the safety distance can be 0.40m.

Ludasirenska.During maintenance or when problems occur the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the power supply should be cut off in a timely manner. After lifting, the aluminum alloy electric elevator should be firmly fixed before maintenance can be carried out. It is strictly prohibited to operate with defects to avoid accidents.

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

.Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

News Abstract: The development of the lifting platform industry will continue to grow in recent years! With the continuous development of electric lifting machinery for high-altitude operations in recent years, the products of electric lifting platform vehicles have been continuously improved, making the further development of lifting platform vehicles possible.


LudasirenskaSmall electric pulley elevatorHow to test insulation



Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

Equal effect.

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

consumption.The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances,LudasirenskaElectric scissor lift, it is allowed to lower the height of the lower door opening, but in any case, the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.


LudasirenskaSmall electric pulley elevatorHow to test insulation



The landing door should meet the requirements of the specifications and achieve standardization.

Production department.Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.

Greater than 0.04s; When the hydraulic buffer is used, the oil level shall be checked, and the action of the hydraulic buffer shall be monitored by the Electrical safety switch. When the hydraulic buffer is compressed, the cage shall not

Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight, greatly saving energy and reducing consumption.

Ludasirenska.Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Monthly maintenance and inspection of hydraulic lifting platform rollers, intermediate shafts and bearings,LudasirenskaScissor fork electric lifting platform, oil cylinder pin shafts and bearings,Ludasirenska2 ton electric elevator, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform, blow out the plunger with compressed air, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.